FAQ
28. EN 50264
Caledonian standard wall and medium wall rolling stock cables conform to EN 50264 for use in power cars(The
corresponding French railway standard is NF F 63826), diesel-electric locomotives, electric and diesel multiple
units EMU / DMU, high- capacity rails, mono rail and light rail vehicles, sleeping cars and passenger coaches.
FIREROL is a kind of widely used rolling stock cables.
Application:
- FIREROL wires combine the advantages of small size, lightweight, high oil resistance, halogen free, high
mechanical properties. They are recommended for installation in railway vehicles (locomotives, trains,
trolleybuses...).
- A 120°C conductor temperature is allowed for a 20000 hours cumulative working time.
The external sheath is mineral oil and fuel oil resistant, ozone and UV resistant.
Conductors:
Flexible stranded tinned copper class 5 according to IEC 60228 with optional separator tape. Conductor
temperature +90 °C
Standard:
EN 50264-1: General requirements applicable to cables, including detailed requirement for the insulating and
sheathing materials
Standard wall rolling stock cables having special fire performance
EN50264-2 = pr EN50264-2-1 |
Standard wall single core cables with crosslinked elastomeric insulation 0.6/1kV Unscreened, unsheathed 1mm2-400mm2 FRL-SW-1SU 1.8/3kV Unscreened, unsheathed 1mm2-400mm2 FRL-SW-3SU |
EN50264-3 = pr |
Standard wall multicore cables with crosslinked elastomeric insulation |
Insulation |
Crosslinked halogen free rubber EI 101 (for A, B, C), EI 102 (for D, E, F), EI 103 (for G, H, J), EI 104 (for K, L, M) and EI 105 (for O, EPDM compound) |
Sheathing |
Special crosslinked halogen free black rubber type: EM 101 (for A, B, C), EM 102 (for D, E, F), EM 103 (for G, H, J), EM 104 (for K, L, M) |
Medium wall rolling stock cables having special fire performance
pr EN50264-3-1: |
Medium wall single core cable with crosslinked elastomeric insulation 0.6/1kV Unscreened, unsheathed 1mm2-400mm2 FRL-MW-1SU 1.8/3kV Unscreened, unsheathed 1mm2-400mm2 FRL-MW-3SU 1.8/3kV Unscreened, sheathed 1mm2-400mm2 FRL-MW-3S |
pr EN50264-3-2: |
Medium wall multicore cables with crosslinked elastomeric insulation |
Insulation |
Crosslinked halogen free black rubber EI 106 (for A, B, C), EI 107 (for D, E, F), EI 108 (for G, H, J), EI 109 (for K, L, M) and EI 110 (for O, EPDM compound) |
Sheathing |
Special crosslinked halogen free rubber type: EM 101 (for A, B, C), EM 102 (for D, E, F), EM 103 (for G, H, J), EM 104 (for K, L, M) |