CCL-VATC-02 |
Product Name/Code : CCL-VATC-02 |
Performance électrique |
Application : |
Electrical Characteristics: |
|
For communication and signal control systems. |
Fréquence |
Atténuation |
Référence à la norme |
(MHz) |
(dB/100m) |
Customer's sample spec. and the general standard |
47 |
4.30 |
100 |
6.00 |
Cable Construction |
230 |
8.90 |
Centre Chef d'orchestre |
Bare Copper |
300 |
10.20 |
Dia.(mm) |
1/1.13 |
400 |
11.80 |
Isolation |
Solid PE |
800 |
17.50 |
Nom. Epaisseur(mm) |
1.8 |
860 |
17.90 |
Isolation Dia. (±0.03mm) |
4.8 |
1000 |
19.50 |
Bonded Al/Polyester Foil |
|
1350 |
23.00 |
Coverage Area(%) |
>=100 |
1750 |
26.3 |
Tinned Copper Braid Shield |
|
2050 |
28.9 |
Construction |
16/ 6/0.12 |
2150 |
29.5 |
Coverage Area(%) |
>=60 |
2400 |
31.3 |
Jacket |
PVC |
|
|
Nom. Epaisseur(mm) |
0.9 |
Température de fonctionnement( ℃ ) |
60 |
Cable Dia.(±0.10mm) |
6.8 |
Capacité(pF/m) |
52 |
Composé Jacket |
PVC/LSF/LSOH |
Impédance(+/-3 Ω ) |
75 |
Identification de base / Code de Couleur |
According to customer request |
Velocity ratio (+/-5%) |
83 |
Rayon de courbure |
6 x Overall Diameter |
|
|
Evaluation de température |
70 ℃ |
|
|
Tension nominale |
300/500V |
|
|
Feu |
|
|
|
Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH)
Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH )
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH )
Smoke Density Test to IEC 61034 ( LSOH )
Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH )
Temperature Index Test to BS 2782 or ISO 4589-3
( LSOH ) |
|
|
|
|