CCL-VATC-03 |
Product Name/Code : CCL-VATC-03 |
Performance électrique |
Application : |
Electrical Characteristics: |
|
For communication and signal control systems. |
Fréquence |
Atténuation |
Référence à la norme |
(MHz) |
(dB/100m) |
Customer's sample spec. and the general standard |
53 |
4.8 |
100 |
6.00 |
Cable Construction |
250 |
9.1 |
Centre Chef d'orchestre |
Bare Copper |
300 |
10.8 |
Dia.(mm) |
1/1.0 |
450 |
12.30 |
Isolation |
Solid PE |
800 |
17.0 |
Nom.Epaisseur(mm) |
1.9 |
880 |
19.10 |
Isolation Dia. (±0.03mm) |
4.8 |
1000 |
19.90 |
Bonded Al/Polyester Foil |
|
1400 |
24.00 |
Coverage Area(%) |
>=100 |
1770 |
27.0 |
Tinned Copper Braid Shield |
|
2000 |
27.9 |
Construction |
16/ 6/0.12 |
2150 |
30.1 |
Coverage Area(%) |
>=60 |
2500 |
33.1 |
Jacket |
PVC |
|
|
Nom. Thickness(mm) |
0.9 |
Température de fonctionnement( ℃ ) |
60 |
Cable Dia.(±0.10mm) |
6.8 |
Capacité(pF/m) |
52 |
Composé Jacket |
PVC/LSF/LSOH |
Impédance(+/-3 Ω ) |
75 |
Identification de base / Code de Couleur |
According to customer request |
Velocity ratio (+/-5%) |
83 |
Rayon de courbure |
6 x Overall Diameter |
|
|
Evaluation de température |
70 ℃ |
|
|
Tension nominale |
300/500V |
|
|
Feu |
|
|
|
Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH)
Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH )
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH )
Smoke Density Test to IEC 61034 ( LSOH )
Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH )
Temperature Index Test to BS 2782 or ISO 4589-3
( LSOH ) |
|
|
|
|