16-2-18C SCREENED |
Product Name/Code:16-2-18C SCREENED |
Performance électrique |
Application: |
Max.Conductor DC Resistance at 20°C(Ω/Km)22.49 |
< 23.70 |
Multi-conductor-audio, control & Instrumentation Cables |
Température de fonctionnement( ℃ )74 |
80 |
Construction |
Tension nominale(V) 1499 |
30 |
6 Core |
Stranded Tinned Copper |
20 ℃ La résistance d'isolement(M Ω .KM) |
> 200 |
AWG |
18 |
|
|
Construction |
T0.20 x 16 |
|
|
Chef d'orchestre Diamètre (mm) |
0.92 |
|
|
Isolation |
PVC |
|
|
Epaisseur |
0.44 |
|
|
Isolation Diamètre(mm) |
1.80 |
|
|
Mylar Spiral (over lapping,%) |
>=25% |
|
|
Screening |
Tinned Copper |
|
|
Construction(mm) |
T0.12 x 16 x 10 |
|
|
Coverage Area(%) |
> 70% |
|
|
Nylon rip cord |
210D |
|
|
Sheathing |
PVC/LSF |
|
|
|
Isolation(mm) |
0.86 |
|
|
|
Diamètre(mm) |
12.5 |
|
|
|
Panneau de revêtement composé |
PVC/LSF/LSOH |
|
|
Identification de base / Code de Couleur |
According to customer request |
|
|
Rayon de courbure |
6xOverall Diameter |
|
|
Evaluation de température |
70°C |
|
|
Tension nominale |
300/500V |
|
|
Feu |
|
|
Flame Propagation Test to IEC 60332 Part 1 and Part 3
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1
Smoke Density Test to IEC 61034
Oxygen Index Test to BS 2863 or ISO 4589-2
Temperatre Index Test to BS 2782 or ISO 4589-3
Fire Resistant Test to IEC 60331-24 |
|
|
|
|
|
|
Website: www.addison-cables.com |
|
|
E-mail: sales@addison-cables.com |
|
|
|