Thermocouple Cables
Part 1 Type 3 PE Insulated Collective Screen Lead SWA PVC Sheathed Thermocouple Cables
Application :
Thermocouple Cables are sensor for measuring temperature, that consists of two dissimilar metals that are joined together at the sensing end. They can be employed as the thermocouple hot junction in addition to serving as the entire wire connection between hot and cold reference junctions.
Types: KX
Conductors: 1.34sqmm Class 5 flexible
Insulation: PE (Polyethylene)
Core identification: See link below
Screen: CAM (Collective aluminium mylar)
Bedding: PE (Polyethylene)
Armour/Protection: LC (Lead alloy)
Bedding: PE (Polyethylene)
Armour/Protection: SWA (Single wire armour)
Sheath/Jacket: PVC (Polyvinyl-Chloride)
Colour: Red
Voltage: 300/500v
Standards: BS4937 International thermocouple reference tables. Extension & compensating cables. Tolerances and identification systems
BS5308 Part 1, Insulated cables, instrumentation, PE
Part 1 Type 3 PE Insulated Collective Screen Lead SWA PVC Sheathed Thermocouple Cables
Size sq
(mm) |
Stranding
(mm) |
|
Diameter over Bedding
(mm) |
Diameter of Armour Wire |
Diameter over Armour
(mm) |
RT of Outer Sheath
(mm) |
Nominal Overall Diameter
(mm) |
App. Weight
(Kg/Km) |
0.5 |
1/0.8 |
0.5 |
5.5 |
7.7 |
9.5 |
1.1 |
11.7 |
467 |
1.3 |
1/1.29 |
0.6 |
6.9 |
9.1 |
10.9 |
1.1 |
13.1 |
563 |
0.5 sqmm (1/0.8mm)
No. of Pairs |
Nominal Diameter Laid Up Pairs
(mm) |
Nominal Diameter Collective Screen
(mm)
|
RT of Inner Bedding
(mm) |
Diameter over Inner Bedding
(mm) |
RT of Lead Alloy Sheath
(mm) |
Diameter over Lead Alloy Sheath
(mm) |
2 |
7.5 |
8.5 |
0.9 |
10.3 |
1.1 |
12.5 |
5 |
10.1 |
11.1 |
1.2 |
13.5 |
1.1 |
14.7 |
10 |
14.9 |
15.9 |
1.2 |
18.3 |
1.2 |
20.7 |
20 |
19.9 |
20.9 |
1.3 |
23.5 |
1.4 |
26.3 |
30 |
23.9 |
24.9 |
1.5 |
27.9 |
1.5 |
30.9 |
50 |
31.1 |
32.1 |
2.0 |
36.1 |
1.8 |
39.7 |
No. of Pairs |
RT of Outer Bedding
(mm) |
Diameter of Outer Bedding
(mm) |
Diameter of Armour Wire
(mm)
|
Diameter over Armour
(mm) |
RT of Outer Sheath
(mm) |
Nominal Overall Diameter
(mm) |
Weight
(Kg/Km)
|
2 |
0.8 |
14.1 |
1.25 |
16.6 |
1.5 |
19.6 |
1140 |
5 |
0.8 |
17.3 |
1.25 |
19.8 |
1.6 |
23.0 |
1450 |
10 |
1.0 |
22.7 |
1.6 |
25.9 |
1.7 |
29.3 |
2300 |
20 |
1.2 |
28.7 |
2.0 |
32.7 |
1.9 |
36.5 |
3580 |
30 |
1.2 |
33.3 |
2.0 |
37.3 |
2.0 |
41.3 |
4470 |
50 |
1.4 |
42.5 |
2.5 |
47.5 |
2.3 |
52.1 |
6780 |
Operating Temperature: Max 105°C, Min -30°C, Min bending 0°C
Min bending radius: 12 X Overall Diameter
Conductor Dimensions
Size & Stranding: 0.5 sqmm (1/0.8mm)
|