Application
This cable is used for interconnection of the distribution boxes and end devices. The cable is very suitable for various indoor and outdoor applications, including routing between buildings within ducts and inside building up to riser shafts.
Description
The Distribution Cable consists of color-coded PVC tight buffered fibers. The fibers are reinforced with aramid yarn for superior strength and contains no metallic elements. The fibers are jacketed with Flame Retardant PVC or LSZH compound.
Propriétés physiques
Nombre fibres |
Poids nominal(kg/km) |
Poids nominal(lb/kft) |
Diamètre extérieur nominal(mm) |
Diamètre extérieur nominal(in) |
Maximum les tractions |
Installation(N/Ib) |
In Service(N/Ib) |
2-6 |
26.0 |
17.45 |
5.0 |
0.197 |
1000/225 |
290/65 |
8-12 |
50.0 |
33.56 |
7.5 |
0.296 |
1425/320 |
500/112 |
14-24 |
140.0 |
93.96 |
13.0 |
0.512 |
2670/600 |
890/200 |
26-36 |
200.0 |
134.23 |
16.5 |
0.650 |
4448/1000 |
1490/335 |
38-48 |
300.0 |
201.34 |
18.0 |
0.709 |
4448/1000 |
1490/335 |
Propriétés mécaniques
Rayon de courbure minimum: |
Force de compression maximale: 2000N |
Under installation: 20×OD |
Repeated Impact: 2.9 N.m (J) 3×2 impacts |
During operation: 10×OD |
Twist (Torsion): 180×10 times, 125×OD |
Gamme de température: |
Cyclic Flexing: 25 cycles for armoured cables |
Operating Temperature Range: -40℃(-40℉) to +70℃(+158℉)
|
100 cycles for unarmoured cables. |
Storage Temperature Range: -50℃(-58℉) to +70℃(+158℉) |
Résistance à l'écrasement: 1485N/cm (850lb/in) |
Fibre de conformité
Température Cyclisme
Résistance à la traction
Crush
Impact
Répétées de flexion
Torsion
Kink
Cable Bend
Cool Bend |
IEC60794-1-2-F2
IEC60794-1-2-E1A
IEC60794-1-2-E3
IEC60794-1-2-E4
IEC60794-1-2-E6
IEC60794-1-2-E7
IEC60794-1-2-E10
IEC60794-1-2-E11
IEC60794-1-2-E11 |
Safety Compliance
General Purpose e année
Riser Grade
Plenum Grade
FRPVC Grade
LSZH Grade
LSFROH Grade
FR Grade |
Flammability Test: OFN(UL1581)
Flammability Test: OFNR/FT4 (UL1666)
Flammability Test: OFNP/FT6(UL 910)
Flammability Test: IEC60332-1
Halogen Content Test: IEC 60754-1
Acidity Test: IEC 60754; Smoke Emission Test: IEC61034-1/2
Halogen Content Test: IEC 60754-1
Acidity Test: IEC 60754; Smoke Emission Test: IEC61034-1/2
Flammability Test: IEC60332-1 & IEC 60332-3C/A
Fire Resistance Test: IEC 60331 / BS 6387 CWZ |
Norme de conformité
GR409-CORE TIA/EIA 568B.3 ICEA-S-83-596
Fonctions
•Used in LAN and distribution applications where compact size and lightweight are required
•Suitable for both indoor and outdoor use - no need for splicing at the building entrance
•Flame-retardant or LSZH version for indoor installations
•Fungus-resistant, water-resistant, and UV-resistant for outdoor installations
•Cable can be armoured for additional protection in direct burial and aerial installations
•Highest specific strength-to-weight ratio for limited conduit space
•Economical for longer distance runs where cable cost is significant
•High quality tight-buffered coating on fiber for environmental and mechanical protection
|