Câbles Fibres Optiques
Central Loose Tube Cable
Application
This cable is characterized by light weight and small diameter, suitable for both aerial and duct installation. The cable can also be used for direct burial for armoured option.
Description
Central loose tube cable contains one tube with 2 - 24 fibers, which is filled with water blocking gel. Either aramid yarn or fiber glass is wound around the tube to provide physical protection and tensile strength. The cable can be jacketed with either PE or LSZH. PE is the preferred option in outdoor environment for water protection purpose. For direct burial, either steel wire armour or corrugated steel tape armour is applied with an optional inner jacket of either PVC, PE or LSZH. An Aluminium moisture tape can be incorporated under the jacket for water blocking and shielding purpose. A ripcord is located under the jacket to facilitate jacket removal.
Construction
Propriétés physiques
Nombre fibres |
Poids nominal(kg/km) |
Poids nominal(lb/kft) |
Diamètre extérieur nominal(mm) |
Diamètre extérieur nominal(in) |
Maximum les tractions |
Installation(N/Ib) |
In Service(N/Ib) |
2-12 |
60.0 |
40.27 |
7.5 |
0.296 |
1500/337 |
445/100 |
14-24 |
65.0 |
43.62 |
8.5 |
0.335 |
1500/337 |
445/100 |
Construction
Propriétés physiques
Nombre fibres |
Poids nominal(kg/km) |
Poids nominal(lb/kft) |
Diamètre extérieur nominal(mm) |
Diamètre extérieur nominal(in) |
Maximum les tractions |
Installation(N/Ib) |
In Service(N/Ib) |
2-12 |
125.0 |
83.89 |
10.5 |
0.414 |
2670/600 |
890/200 |
14-24 |
145.0 |
97.32 |
12.0 |
0.473 |
2670/600 |
890/200 |
Construction
Propriétés physiques
Nombre fibres |
Poids nominal(kg/km) |
Poids nominal(lb/kft) |
Diamètre extérieur nominal(mm) |
Diamètre extérieur nominal(in) |
Maximum les tractions |
Installation(N/Ib) |
In Service(N/Ib) |
2-12 |
170.0 |
114.09 |
10.5 |
0.414 |
8000/1800 |
2650/595 |
14-24 |
245.0 |
164.43 |
12.0 |
0.473 |
8000/1800 |
2650/595 |
Propriétés mécaniques
Rayon de courbure minimum: |
|
Force de compression maximale: |
3000N |
Under installation: |
20×OD |
Repeated Impact: |
4.4 N.m (J) |
During operation |
10×OD for unarmoured cables |
Twist (Torsion): |
180×10 times, 125×OD |
|
20×OD for armoured cables |
Cyclic Flexing: |
25 cycles for armoured cables. |
Gamme de température: |
|
|
100 cycles for unarmoured cables. |
Operating Temperature Range: |
-40℃(-40℉) to +70℃(+158℉) |
Résistance à l'écrasement: |
263N/cm (150lb/in) |
Storage Temperature Range: |
-50℃(-58℉) to +70℃(+158℉) |
|
|
Fibre de conformité
Température Cyclisme
Résistance à la traction
Crush
Impact
Répétées de flexion
Torsion
Kink
Cable Bend
Cool Bend |
IEC60794-1-2-F2
IEC60794-1-2-E1A
IEC60794-1-2-E3
IEC60794-1-2-E4
IEC60794-1-2-E6
IEC60794-1-2-E7
IEC60794-1-2-E10
IEC60794-1-2-E11
IEC60794-1-2-E11 |
Safety Compliance
General Purpose Grade |
Flammability Test: OFN (UL1581) |
Riser Grade |
Flammability Test: OFNR/FT4 (UL1666) |
Plenum Grade |
Flammability Test: OFNP/FT6 (UL 910) |
FRPVC Grade |
Flammability Test: IEC60332-1 |
LSZH Grade |
Halogen Content Test: IEC 60754-1
Acidity Test: IEC 60754;
Smoke Emission Test: IEC61034-1/2 |
LSFROH Grade |
Halogen Content Test: IEC 60754-1
Acidity Test: IEC 60754;
Smoke Emission Test: IEC61034-1/2
Flammability Test: IEC60332-1 & IEC 60332-3C/A |
FR Grade |
Fire Resistance Test : IEC 60331 / BS 6387 CWZ |
Norme de conformité
Telcordia GR-20 RUS 7 CFR 1755.900 (REA PE-90) ICEA S 87-640
Fonctions
•Loose Tube construction provides environmental protection
•Loose tube jelly filled for superior fiber protection
•Colored coded fibers and binders for quick and easy identification during installation.
•Very lightweight and flexible design allows for easy installation
•UV or moisture resistant for outdoor application
•Compact design with small cable diameter
•All Dielectric strength member
•Anti-termite and rodent protection as options
•Optional Aluminium moisture barrier for EMI protection
|