Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Marine Cable  

Marine Cable

Cat5E UTP/FTP Armoured Data Cable

Applications :

  • Cat5E Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for basic voice and data installations up to 100 MHz. In addition, these cables are with copper wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable.

Standards :

  • IEC 60332-3-22 IEC 60754-1,2
    IEC 61034-1,2 NEK 606:2004
 

 

Construction :

  • Conductors : 24AWG solid bare copper.
  • Insulation : HDPE.
  • Twinning : Two coloured insulated conductors twisted together to form a pair.
  • Bedding : Flame retardant, low smoke and halogen-free polyolefin, coloured black.
  • Armour : 0.2/0.3mm copper wire braid.
  • Outer Sheath : Low smoke and halogen-free polyolefin.

Optional :

  • Cat5E F/UTP : These cables have collective shielding of aluminium/Polyester tape with drain wire.
  • Cat5E SF/UTP :These cables have double collective shieldings of aluminium/Polyester tape & copper wire braid with drain wire

 

Electrical Characteristics :

  • AWG   18
    Nominal Conductor Diameter mm 1.0
    Maximum DC Resistant@20℃ Ω/100m 9.38
    Maximum DCR Unbalance % 5
    Maximum Mutual Capacitance pF/m 55.8
    Maximum Capacitance Unbalance pF/100m 330
    Characteristic Impedance@1-100MHz Ω 100+/-15
    Maximum Propagation Delay Skew ns/100m 45
  • FREQ MHz Maximum Attenuation dB/100m Minimum NEXT dB Minimum PSNEXT dB Minimum ELFEXT dB/100m Minimum PSELFEXT dB/100m Minimum RL dB
    0.772 1.8 67.0 64.0 66.0 63.0
    1 2.0 65.3 62.3 63.8 60.8 20.0
    4 4.1 56.3 53.3 51.7 48.7 23.0
    8 5.8 51.8 48.8 45.7 42.7 24.5
    10 6.5 50.3 47.3 43.8 40.8 25.0
    16 8.2 47.3 44.3 39.7 36.7 25.0
    20 9.3 45.8 42.8 37.7 34.7 25.0
    25 10.4 44.3 41.3 35.8 32.8 24.3
    31.25 11.7 42.9 39.9 33.9 30.9 23.6
    62.5 17.0 38.4 35.4 27.8 24.8 21.5
    100 22.0 35.3 32.3 23.8 20.8 20.1

Mechanical and Thermal Properties :

  • Bending Radius : 8×OD (during installation); 4×OD (fixed installed).
  • Temperature Range : -30℃ ~ +75℃.

Dimensions and Weight :

 

Construction No. of elements×No. of cores in element×Conductor diameter
(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
Inner Outer
4×2×0.53 0.2 0.8 1.2 11.2 208