Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Marine Cable  

Marine Cable

S12 RU(c) 250 V

Applications :

  • These unarmoured cables are flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.

Standards :

  • IEC 60092-376 IEC 60092-351
    IEC 60092-359 IEC 60332-1
    IEC 60332-3-22 IEC 60754-1,2
    IEC 61034-1,2 NEK 606:2004
 

 

Construction :

  • Conductors : Circular tinned annealed stranded copper wire to IEC 60228 class 2.
  • Insulation : Halogen free EPR compound.
  • Twinning : Colour coded cores twisted together.
  • Collective Shielding : Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.
  • Outer Sheath : Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).

Electrical Characteristics :

  • Nominal Cross Section Area mm² 0.75 1.0 1.5
    Nominal Conductor Diameter mm 1.1 1.3 1.6
    Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9
    Mutual Capacitance nF/km 80 90 100
    Nominal Inductance@1KHz MH/km 0.682 0.645 0.632
    Maximum L/R@1KHz μH/Ω 20 25 35
    Operating Voltage V 250 250 250

Mechanical and Thermal Properties :

  • Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
  • Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight :

Construction No. of elements×No. of cores in element×Cross section
(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
2×2×0.75 0.6 1.1 9.4 160
4×2×0.75 0.6 1.1 11.5 215
7×2×0.75 0.6 1.3 13.6 300
8×2×0.75 0.6 1.3 14.7 340
12×2×0.75 0.6 1.4 17.6 465
16×2×0.75 0.6 1.5 19.7 595
19×2×0.75 0.6 1.5 20.7 665
24×2×0.75 0.6 1.7 24.1 850
32×2×0.75 0.6 2.0 26.7 1065
2×3×0.75 0.6 1.1 11.0 170
3×3×0.75 0.6 1.1 12.1 235
4×3×0.75 0.6 1.2 13.1 280
7×3×0.75 0.6 1.4 15.7 410
8×3×0.75 0.6 1.4 17.5 490
12×3×0.75 0.6 1.5 20.6 645
16×3×0.75 0.6 1.6 23.1 835
19×3×0.75 0.6 1.7 24.3 940
24×3×0.75 0.6 1.8 28.2 1210
2×2×1.0 0.6 1.1 9.9 190
4×2×1.0 0.6 1.1 12.3 255
7×2×1.0 0.6 1.3 14.7 370
8×2×1.0 0.6 1.3 15.7 410
12×2×1.0 0.6 1.5 18.9 565
16×2×1.0 0.6 1.6 21.1 730
19×2×1.0 0.6 1.7 22.5 830
24×2×1.0 0.6 1.8 25.9 1050
32×2×1.0 0.6 2.1 28.7 1315
3×3×1.0 0.6 1.1 12.9 280
4×3×1.0 0.6 1.3 14.0 335
7×3×1.0 0.6 1.5 16.9 500
12×3×1.0 0.6 1.6 22.1 795
16×3×1.0 0.6 1.6 24.8 1025
19×3×1.0 0.6 1.8 26.3 1175
24×3×1.0 0.6 2.0 30.4 1490
2×2×1.5 0.7 1.2 11.3 250
4×2×1.5 0.7 1.2 14.1 345
7×2×1.5 0.7 1.4 17.2 515
8×2×1.5 0.7 1.4 18.4 575
12×2×1.5 0.7 1.6 22.4 810
16×2×1.5 0.7 1.7 25.0 1045
19×2×1.5 0.7 1.8 26.4 1175
24×2×1.5 0.7 1.9 30.7 1505
32×2×1.5 0.7 2.2 33.9 1890
2×3×1.5 0.7 1.2 13.5 265
3×3×1.5 0.7 1.2 14.9 380
4×3×1.5 0.7 1.3 16.3 465
7×3×1.5 0.7 1.5 19.8 705
8×3×1.5 0.7 1.5 21.5 820
12×3×1.5 0.7 1.7 26.2 1140
16×3×1.5 0.7 1.8 29.4 1475
19×3×1.5 0.7 1.9 30.9 1675
24×3×1.5 0.7 2.1 36.2 2160