Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Marine Cable  

Marine Cable

S15 BFOU-HCF(i) 250 V

Applications :

  • These cables are fire resistant, flame retardant, low smoke and halogen free, used for emergency instrumentation, communication, control and alarm systems that need to be operational during a 1100℃ hydrocarbon fire.

Standards :

  • IEC 60092-376 IEC 60092-351
    IEC 60092-359 IEC 60332-1
    IEC 60332-3-22 IEC 60754-1,2
    IEC 61034-1,2 NEK 606:2004
    IEC 60331-21  
 

 

Construction :

  • Conductors : Circular tinned annealed stranded copper wire to IEC 60228 class 2.
  • Insulation : Mica tape + Halogen free EPR compound.
  • Twinning : Colour coded cores twisted together.
  • Individual Shielding : Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.
  • Bedding : Halogen free compound.
  • Armour : Tinned copper wire braid.
  • Outer Sheath1 : Halogen free thermosetting compound, SHF2.
  • HC-fire protection : Extruded thermoplastic fire protection compound.
  • Taping : Lapped glass fibre tape.
  • Outer Sheath2 : Flame retardant halogen-free thermoplastic compound, type SHF1, coloured grey (blue for intrinsically safe).

Electrical Characteristics :

  • Nominal Cross Section Area mm² 1.5
    Nominal Conductor Diameter mm 1.6
    Maximum Resistant@20℃ Ω/km 12.9
    Mutual Capacitance nF/km 100
    Nominal Inductance@1KHz MH/km 0.673
    Operating Voltage V 250

Mechanical and Thermal Properties :

  • Bending Radius : 20×OD (during installation); 12×OD (fixed installed).
  • Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight :

Construction No. of elements×No. of cores in element×Cross section
(mm²)
Nominal Insulation Thickness
mm
Nominal Diameter Over Bedding
mm
Nominal Diameter Over Sheath1
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
1×2×1.5 0.7 9.0 13.1 39.5 1880
2×2×1.5 0.7 13.0 16.8 44.5 2450
4×2×1.5 0.7 15.0 20.7 47.5 2830
8×2×1.5 0.7 21.0 26.4 54.0 3690
12×2×1.5 0.7 25.0 31.2 63.0 5200