Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Thermocouple Cables 

Thermocouple Cables

Part 1 Type 2 XLPE Insulated Individual & Collective Screen SWA LSF Sheathed Thermocouple Cables

Application :
Thermocouple Cables are sensor for measuring temperature, that consists of two dissimilar metals that are joined together at the sensing end. They can be employed as the thermocouple hot junction in addition to serving as the entire wire connection between hot and cold reference junctions.

Types: KX

Conductors: 1.0sqmm class 1 solid copper

Insulation: XLPE (Cross linked polyethylene)

Core identification: See link below

Screen: IAM (Individual aluminium Mylar) & CAM (Collective aluminium mylar)

Bedding: LSZH (Low smoke zero halogen)

Armour/Protection: SWA (Single wire armour)

Sheath/Jacket: LSZH (Low smoke zero halogen)

Colour: Green

Voltage: 300/500V

Standards: BS4937 International thermocouple reference tables. Extension & compensating cables. Tolerances and identification systems

BS5308 Part 1, Insulated cables, instrumentation, PE

Part 1 Type 2 XLPE Insulated Individual & Collective Screen SWA LSF Sheathed Thermocouple Cables

Size sq
(mm)

Stranding
(mm)

RT of Insulation
(mm)
Diameter over Bedding
(mm)
Diameter of Armour Wire

Diameter over Armour
(mm)

RT of Outer Sheath
(mm)

Nominal Overall Diameter
(mm)

App. Weight
(Kg/Km)

0.5

1/0.8

0.5
5.5
0.9

7.3

1.0

9.3

142

1.3

1/1.29

0.6
6.9
0.9

8.7

1.0

10.7

185

0.5 sqmm (1/0.8mm)

No. of Pairs

Nominal Diameter Laid Up Pairs
(mm)

Nominal Diameter Collective Screen
(mm)
RT of Bedding
(mm)
Diameter over Bedding
(mm)

Diameter of Armour Wire
(mm)

Diameter over Armour
(mm)

Nominal Overall Diameter
(mm)

App. Weight
(Kg/Km)

2

7.7

8.7
0.8
10.3

0.9

12.1

14.9

380

5
10.1
11.1
1.2
13.5
1.25
16.0
19.0
660
10
14.9
15.9
1.2
18.3
1.25
20.8
24.2
950
15
15.9
16.9
1.3
19.5
1.6
22.7
27.3
1291
20
19.9
20.9
1.3
23.5
1.6
26.7
30.3
1560
30
23.9
24.9
1.5
27.9
1.6
31.1
34.9
1990

50

31.1

32.1
2.0
36.1

2.0

40.1

44.5

3200

Operating Temperature: Max 105°C, Min -30°C, Min bending 0°C

Min bending radius: 6 X Overall Diameter

Conductor Dimensions

Size & Stranding: 0.5 sqmm (1/0.8mm)