Thermocouple Cables
Part 2 Type 3 PVC Insulated Individual & Collective Screen Lead SWA PVC Sheathed Thermocouple Cables
Application :
Thermocouple Cables are sensor for measuring temperature, that consists of two dissimilar metals that are joined together at the sensing end. They can be employed as the thermocouple hot junction in addition to serving as the entire wire connection between hot and cold reference junctions.
Types: VX
Conductors: 0.5sqmm class 1 solid
Insulation: PVC (Polyvinyl Chloride)
Screen: IAM (Individual aluminium mylar) & CAM (Collective aluminium mylar)
Bedding: PVC (Polyvinyl Chloride)
Armour/Protection: LC (Lead alloy)
Bedding: PVC (Polyvinyl Chloride)
Armour/Protection: SWA (Single wire armour)
Sheath/Jacket: PVC (Polyvinyl Chloride)
Colour: Blue
Voltage: 300/500V
Standards: BS4937 International thermocouple reference tables. Extension & compensating cables. Tolerances and identification systems
BS5308 Part 2, Insulated cables, instrumentation, PVC
Part 2 Type 3 PVC Insulated Individual & Collective Screen Lead SWA PVC Sheathed Thermocouple Cables
Size sq
(mm) |
Stranding
(mm) |
|
Diameter over Bedding
(mm) |
Diameter of Armour Wire |
Diameter over Armour
(mm) |
RT of Outer Sheath
(mm) |
Nominal Overall Diameter
(mm) |
App. Weight
(Kg/Km) |
0.5 |
1/0.8 |
0.5 |
5.5 |
7.7 |
9.5 |
1.1 |
11.7 |
467 |
1.3 |
1/1.29 |
0.6 |
6.9 |
9.1 |
10.9 |
1.1 |
13.1 |
563 |
0.5 sqmm (1/0.8mm)
No. of Pairs |
Nominal Diameter Laid Up Pairs
(mm) |
Nominal Diameter Collective Screen
(mm)
|
RT of Inner Bedding
(mm) |
Diameter over Inner Bedding
(mm) |
RT of Lead Alloy Sheath
(mm) |
Diameter over Lead Alloy Sheath
(mm) |
2 |
7.5 |
8.5 |
0.9 |
10.3 |
1.1 |
12.5 |
5 |
10.1 |
11.1 |
1.2 |
13.5 |
1.1 |
14.7 |
10 |
14.9 |
15.9 |
1.2 |
18.3 |
1.2 |
20.7 |
20 |
19.9 |
20.9 |
1.3 |
23.5 |
1.4 |
26.3 |
30 |
23.9 |
24.9 |
1.5 |
27.9 |
1.5 |
30.9 |
50 |
31.1 |
32.1 |
2.0 |
36.1 |
1.8 |
39.7 |
No. of Pairs |
RT of Outer Bedding
(mm) |
Diameter of Outer Bedding
(mm) |
Diameter of Armour Wire
(mm)
|
Diameter over Armour
(mm) |
RT of Outer Sheath
(mm) |
Nominal Overall Diameter
(mm) |
Weight
(Kg/Km)
|
2 |
0.8 |
14.1 |
1.25 |
16.6 |
1.5 |
19.6 |
1140 |
5 |
0.8 |
17.3 |
1.25 |
19.8 |
1.6 |
23.0 |
1450 |
10 |
1.0 |
22.7 |
1.6 |
25.9 |
1.7 |
29.3 |
2300 |
20 |
1.2 |
28.7 |
2.0 |
32.7 |
1.9 |
36.5 |
3580 |
30 |
1.2 |
33.3 |
2.0 |
37.3 |
2.0 |
41.3 |
4470 |
50 |
1.4 |
42.5 |
2.5 |
47.5 |
2.3 |
52.1 |
6780 |
Operating Temperature: Max 105°C, Min -30°C, Min bending 0°C
Min bending radius: 12 X Overall Diameter
Conductor Dimensions
Size & Stranding: 0.5 sqmm (1/0.8mm)
|