Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
    Fiber Optic Kabels 
 

Mechanical & Environmental Properties for Single Mode Fiber

Testing Parameters

EIA/TIA-455 FOTP Number

IEC-794-1 Test Method

EN 187000Test Method

Maximum Increased loss

Tensile Load & Bending

33

E1

501

<0.05dB (90%); <0.15dB (100%)

Low & HighTemperature Bend

37

E11

<0.05dB (90%); <0.15dB (100%)

Compression loading (Crush)

41

E3

504

<0.05dB (90%); <0.15dB (100%) 440N/km(250lb/in) load

Impact Resistance

25

E4

505

<0.05dB (90%); <0.15dB (100%)

Twist (Torson)

85

E7

508

<0.05dB (90%); <0.15dB (100%)

Cyclic Flexing(Repeated Bending)

104

E6

509

<0.05dB (90%); <0.15dB (100%)

External freezing

98

F6

<0.05dB (90%); <0.15dB (100%)

Temperature Cycling

3

F1

601

<0.05dB (90%); <0.15dB (100%)

Fiber Stripability

178

B6

<8.9N(2lbf) on unaged and aged fi ber; >1.3N(0.3lbf) on unaged and aged fi ber

Cable Aging

82

F5

<0.1dB (90%); <0.25dB (100%)

Water Penetration

82

F5

No flow after 24 hours from 1 meter length of cable

Compound Flow (Drip)

81

E14

80 C 24 hrs duration, no drip

Mechanical & Environmental Properties for Multi Mode Fiber

Testing Parameters

EIA/TIA-455 FOTP Number

IEC-794-1 Test Method

EN 187000 Test

MethodMaximum Increased loss

Tensile Load & Bending

33

E1

501

<0.2dB

Low & HighTemperature Bend

37

E11

<0.4dB

Compression loading (Crush)

41

E3

504

<0.2dB 440N/km(250lb/in) load

Cyclic Impact

25

E4

505

<0.4dB

Twist (Torsion)

85

E7

508

<0.2dB

Cyclic Flexing(Repeated Bending)

104

E6

509

<0.2dB

External freezing

98

F6

<0.2dB

Temperature Cycling

3

F1

601

<0.05dB (90%); <0.15dB (100%)

Fiber Stripability

178

B6

<13.4N(3lbf) on unaged fi ber

Cable Aging

82

F5

<0.1dB (90%); <0.25dB (100%)

Water Penetration

82

F5

No flow after 24 hours from 1 meter length of cable

Compound Flow (Drip)

81

E14

80 C 24 hrs duration, no drip