Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H03V2V2-F/H03V2V2H2-F

Application and Description

These cables are suitable for domestic premises, kitchen, office for light service or light portable
apparatuses. With their special insulation and sheath compounds these cables are adapt for apparatus in
kitchen and heating and for use in zones with high temperatures (like lighting system apparatuses) without
contact with warm parts and radiations. Unsuitable for outdoor use, in industrial and agricultural buildings
or non-domestic portable tools. The maximum conductor temperature in normal use: 90°C.While high
temperature use, skin contact must be avoided.

Standard and Approval

<HAR>HD 21.12; HD 308 S2 DIN VDE 0281 part 1, part 12; DIN VDE 0293 part 308; DIN VDE 0295
CEI 20-20/12, CEI 20-35 (EN60332-1) / CEI 20-37 (EN50267), EN50265-2-1

Cable Construction

- Bare copper fine wire conductor
- Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383
- PVC core insulation T13 to VDE-0281 Part 1
- Color coded to VDE-0293-308
- PVC outer jacket TM3

            

Technical Characteristics

- Working voltage: 300/300 volts
- Test voltage: 3000 volts
- Flexing bending radius: 15 x Ø
- Static bending radius: 4 x Ø
- Flexing temperature: +5º C to +90º C
- Static temperature: -40º C to +90º C
- Short circuit temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km

         

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
H03V2V2-F
2 x 0.50
0.5
0.6
5
9.6
38
20(16/32)
3 x 0.50
0.5
0.6
5.4
14.4
45
20(16/32)
4 x 0.50
0.5
0.6
5.8
19.2
55
2 x 0.75
0.5
0.6
5.5
14.4
46
18(24/32)
3 x 0.75
0.5
0.6
6
21.6
59
18(24/32)
4 x 0.75
0.5
0.6
6.5
28.8
72
H03V2V2H2-F
20(16/32)
2 x 0.50
0.5
0.6
3.2 x 5.2
9.7
32
2 x 0.75
0.5
0.3
3.4 x 5.6
14.4
35