Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05BQ-F/H07BQ-F(NGMH11YÖ)

Application and Description

These cables are used for medium mechanical stress in dry, damp or wet areas, e.g. for connecting
agricultural and commercial equipment, for connecting heaters where there is a danger of cable damage due
to its contact with hot surfaces. The cable can also be used in electrical appliances such as drills, hand-held
circular saws as well as in building sites and refrigeration plants. H07BQ-F can commonly be found in other
machinery in agriculture, building sites, docks and refrigeration plants. The robust PUR jacket adds abrasion,
notch and tear resistance as well as chemical resistance to oils, fats, petrol, water, ozone, UV radiation,
hydrolysis and microbes. Common European designation is NGMH11YÖ.

Standard and Approval

<HAR> HD22.10 S1, VDE-0282 Part-10, CEI 20-19 p.10, CE low voltage directive 73/23/EEC & 93/68/EEC.,
IEC 60245-4, ROHS compliant

Cable Construction

- Fine bare or tinned copper strands
- Strands to VDE-0295 Class-5, IEC 60228 and HD383 Class-5
- Rubber compound insulation E16 to VDE-0282 Part-1
- Color coded to VDE-0293-308
- Conductors stranded in layers with optimal lay-length
- Green-yellow earth core in the outer layer
- Polyurethane/PUR outer jacket TMPU- orange (RAL 2003)

Technical Characteristics

- Working voltage: 300/500 volts(H05BQ-F), 450/750 volts(H07BQ-F)
- Test voltage: 2000 volts(H05BQ-F), 2500 volts(H07BQ-F}
- Flexing bending radius: 5 x Ø
- Fixed bending radius: 3 x Ø
- Flexing Temperature: -40º C to +80º C
- Fixed Temperature: -50º C to +90º C
- Short circuit Temperature: +250º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km

           

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath
mm
Nominal Overall ameter
mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
18(24/32)
2 x 0.75
0.6
0.8
5.7 - 7.4
14.4
52
18(24/32)
3 x 0.75
0.6
0.9
6.2 - 8.1
21.6
63
18(24/32)
4 x 0.75
0.6
0.9
6.8 - 8.8
29
80
18(24/32)
5 x 0.75
0.6
1.0
7.6 - 9.9
36
96
17(32/32)
2 x 1
0.6
0.9
6.1 - 8.0
19.2
59
17(32/32)
3 x 1
0.6
0.9
6.5 - 8.5
29
71
17(32/32)
4 x 1
0.6
0.9
7.1 - 9.3
38.4
89
17(32/32)
5 x 1
0.6
1.0
8.0 - 10.3
48
112
H07BQ-F
16(30/30)
2 x 1.5
0.8
1.0
7.6 - 9.8
29
92
16(30/30)
3 x 1.5
0.8
1.0
8.0 - 10.4
43
109
16(30/30)
4 x 1.5
0.8
1.1
9.0 - 11.6
58
145
16(30/30)
5 x 1.5
0.8
1.1
9.8 - 12.7
72
169
14(50/30)
2 x 2.5
0.9
1.1
13.0 - 15.0
101
230
14(50/30)
3 x 2.5
0.9
1.1
17.0 - 20.0
173
398
14(50/30)
4 x 2.5
0.9
1.2
9.0 - 11.6
48
121
14(50/30)
5 x 2.5
0.9
1.3
9.6 - 12.4
72
164
12(56/28)
2 x 4
1.0
1.2
10.7 - 13.8
96
207
12(56/28)
3 x 4
1.0
1.2
11.9 - 15.3
120
262
12(56/28)
4 x 4
1.0
1.3
10.6 - 13.7
77
194
12(56/28)
5 x 4
1.0
1.4
11.3 - 14.5
115
224
10(84/28
2 x 6
1.0
1.3
12.7 - 16.2
154
327
10(84/28
3 x 6
1.0
1.4
14.1 - 17.9
192
415
10(84/28
4 x 6
1.0
1.5
11.8 - 15.1
115
311
10(84/28
5 x 6
1.0
1.6
12.8 - 16.3
173
310