Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05G-U/H07G-U/R

Application and Description

These cables are recommended for the internal wiring of switchboards and distributor boards as well as
in operating parts in or on lights. The higher temperature range allows for connections to heaters with an
alternating nominal voltage of 1000V. or direct nominal voltage of 750V. These cables are all allowed for
laying in tubes in and under plaster.

Standard and Approval

<HAR> HD 22.7 S2, VDE-0282 Part-7, CEI 20-19/7, CEI 20-35(EN60332-1), CE Low Voltage Directive
73/23/EEC and 93/68/EEC, ROHS compliant

Cable Construction

- Solid bare copper / strands
- Strands to VDE-0295 Class-1/2, IEC 60228 Class-1/2
- Rubber compound type EI3 (EVA) to DIN VDE 0282 part 7 insulation
- Cores to VDE-0293 colors

          

Technical Characteristics

- Working voltage: 300/500v (H05G-U), 450/750v (H07G-U/R)
- Test voltage: 2000volts (H05G-U), 2500 volts (H07G-U/R)
- Flexing bending radius: 7 x Ø
- Static bending radius: 7 x Ø
- Flexing temperature: -25º C to +110º C
- Static temperature: -40º C to +110º C
- Short circuit Temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 10 MΩ x km

           

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation
mm
Nominal
Overall iameter mm
Nominal Copper Weight kg/km
Nominal Weight kg/km
H05G-U
20
1×0.5
0.6
2.1
4.8
9
18
1×0.75
0.6
2.3
7.2
12
17
1×1
0.6
2.5
9.6
15
H07G-U
16
1×1.5
0.8
3.1
14.4
21
14
1×2.5
0.9
3.6
24
32
12
1×4
1
4.3
38
49
H07G-R
10(7/18)
1×6
1
5.2
58
70
8(7/16)
1×10
1.2
6.5
96
116
6(7/14)
1×16
1.2
7.5
154
173
4(7/12)
1×25
1.4
9.2
240
268
2(7/10)
1×35
1.4
10.3
336
360
1(7/13)
1×50
1.6
12
480
487