  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05V-R/H07V-R

Application and Description

These cables are preferably for installation indoors, in cable ducts and in industrial plants or switching
stations, under ground installation. Can be used in switchboards and distributor boards or where a thicker
strand of multi-wire is required. Found in electronic and electrical equipment and switchgear cabinets
designed for export to a European country and for MRO replacement of European made equipment wire.

Standard and Approval

<HAR> HD 21.3 S3, BS 6004, VDE-0281 Part-3, CEI 20-20/3 , CEI 20-35 (EN60332-1)
CEI 20-52, CE Low Voltage Directive 73/23/EEC and 93/68/EEC, ROHS compliant

Cable Construction

- Bare copper solid/strands conductor
- Strands to VDE-0295 Class-2, IEC 60228 Cl-2
- Special PVC TI1 core insulation
- Cores to VDE-0293 colors on chart

Technical Characteristics

- Working voltage: 300/500 volts(H05V-R), 450/750 volts(H07V-R)
- Test voltage: 2000 volts(H05V-R), 2500 volts(H07V-R)
- Flexing bending radius: 15 x Ø
- Static bending radius: 15 x Ø
- Flexing temperature: -5º C to +70º C
- Static temperature: -30º C to +80º C
- Short circuit temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 10 MΩ x km

           

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Overall Diameter
mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
H05V-R
20(7/29)
1 x 0.5
0.6
2.2
4.8
9
18(7/27)
1 x 0.75
0.6
2.4
7.2
12
17(7/26)
1 x 1
0.6
2.6
9.6
15
16(7/24)
1 x 1.5
0.7
3.0
14.4
23
14(7/22)
1 x 2.5
0.8
3.6
24
35
12(7/20)
1 x 4
0.8
4.2
39
51
10(7/18)
1 x 6
0.8
4.7
58
71
8(7/16)
1 x 10
1.0
6.1
96
120
6(7/14)
1 x 16
1.0
7.2
154
170
4(7/12)
1 x 25
1.2
8.4
240
260
2(7/10)
1 x 35
1.2
9.5
336
350
1(19/13)
1 x 50
1.4
11.3
480
480
2/0(19/11)
1 x 70
1,4
12.6
672
680
3/0(19/10)
1 x 95
1,6
14.7
912
930
4/0(37/12)
1 x 120
1,6
16.2
1152
1160
300MCM(37/11)
1 x 150
1,8
18.1
1440
1430
350MCM(37/10)
1 x 185
2,0
20.2
1776
1780
500MCM(61/11)
1 x 240
2,2
22.9
2304
2360
1 x 300
2.4
24.5
2940
1 x 400
2.6
27.5
3740