Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05V2-K/H07V2-K

Application and Description

These special heat-resistant flexible single-conductor hook-up wires are ideal for use in power current
installation, switch cabinets, motors and transformers which are subject to direct contact with high
temperature (e.g. varnishing machines and drying towers etc.). These are also suitable for inside wiring of
electrical equipments such as lighting and heating apparatus.

Standard and Approval

<HAR> HD 21.7 S2, CEI 20-20, CEI20-52, VDE-0281 Part-7,
CE Low Voltage Directive 73/23/EEC and 93/68/EEC,ROHS compliant

Cable Construction

- Fine bare copper strands
- Strands to VDE-0295 Class-5, IEC 60228 Class-5, BS 6360 cl. 5 and HD 383
- Special heat resistant PVC TI3 core insulation to DIN VDE 0281 part 7
- Cores to VDE-0293 colors
- H05V2-K (20, 18 & 17 AWG)
- H07V2-K (16 AWG and Larger)

Technical Characteristics

- Working voltage: 300/500v (H05V2-K)/ 450/750v (H07V2-K)
- Working voltage: - Test voltage: 2000 volts
- Flexing bending radius: 10-15 x Ø
- Static bending radius: 10-15 x Ø
- Flexing temperature: +5º C to +90º C
- Static temperature: -10º C to +105º C
-Short circuit temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km

          

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Overall Diameter
mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
H05V2-K
20(16/32)
1 x 0.5
0.6
2.5
4.8
8.7
18(24/32)
1 x 0.75
0.6
2.7
7.2
11.9
17(32/32)
1 x 1
0.6
2.8
9.6
14.0
H07V2-K
16(30/30)
1 x 1.5
0,7
3.4
14.4
20
14(50/30)
1 x 2.5
0,8
4.1
24
33.3
12(56/28)
1 x 4
0,8
4.8
38
48.3
10(84/28)
1 x 6
0,8
5.3
58
68.5
8(80/26)
1 x 10
1,0
6.8
96
115
6(128/26)
1 x 16
1,0
8.1
154
170
4 (200/26)
1 x 25
1,2
10.2
240
270
2 (280/26)
1 x 35
1,2
11.7
336
367
1 (400/26)
1 x 50
1,4
13.9
480
520
2/0 (356/24)
1 x 70
1,4
16
672
729
3/0 (485/24)
1 x 95
1,6
18.2
912
962
4/0 (614/24)
1 x 120
1,6
20.2
1115
1235
300 MCM(765/24)
1 x 150
1,8
22.5
1440
1523
350 MCM(944/24)
1 x 185
2,0
24.9
1776
1850
500MCM(1225/24)
1 x 240
2,2
28.4
2304
2430