Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05VV-F/SJT

Application and Description

These cables are suited to be used for cooking and heating apparatus under the condition that cable does
not come in direct contact with hot parts of the apparatus and no other influences or heat. The cables
are suitable for fixed installation in furniture, partition walls, decoration covering and in hollow spaces of
prefabricated building parts. They are not suitable for use in open air, in industries (also permitted to tailor
workshops and of that kind) and in agriculture plants and for connecting commercial electrical tools.

Standard and Approval

<HAR> HD21.5 S3, VDE-0281 Part-5 & Part-2, UL Style 62 (SJT), VW-1, CSA 22.2 No 49, FT-1,
CE low voltage directive 73/23/EEC & 93/68/EEC., IEC 60227-5, ROHS compliant

Cable Construction

- - Bare copper fine wire conductor
- Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383
- PVC core insulation T12 to VDE-0281 Part 1
- Color coded to VDE-0293-308
- Green-yellow grounding (3 conductors and above)
- PVC outer jacket TM2

Technical Characteristics

- Working voltage VDE: 300/500 volts
- Working Voltage UL/CSA: 300 volts
- Test voltage: 2000 volts
- Flexing bending radius: 7.5 x Ø
- Static bending radius: 4 x Ø
- Flexing temperature: -5º C to +70º C
- Static temperature: -40º C to +70º C
- Flame retardant: IEC 60332.1, VW-1
- Insulation resistance: 20 MΩ x km

          

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
NominaWeight kg/Km
17(32/32)
2 x 1
0.6
0.8
7.2
19.2
56
17(32/32)
3 x 1
0.6
0.8
7.6
28.8
73
17(32/32)
4 x 1
0.6
0.9
8.6
38.4
86
17(32/32)
5 x 1
0.6
0.9
9.4
48
105
16(30/30)
2 x 1.5
0.7
0.8
7.6
28
82
16(30/30)
3 x 1.5
0.7
0.9
8.3
44
96
16(30/30)
4 x 1.5
0.7
1
9.3
58
117
16(30/30)
5 x 1.5
0.7
1.1
10.4
72
144
14(30/50)
2 x 2.5
0.8
1
9.2
48
118
14(30/50)
3 x 2.5
0.8
1.1
10
72
152
14(30/50)
4 x 2.5
0.8
1.1
10.9
96
192
14(30/50)
5 x 2.5
0.8
1.2
12.2
120
243
12(56/28)
2 x 4
0.8
1.1
10.6
76
195
12(56/28)
3 x 4
0.8
1.2
11.5
115
235
12(56/28)
4 x 4
0.8
1.2
12.4
154
300
12(56/28)
5 x 4
0.8
1.4
14.1
192
361