Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05VVH6-F/H07VVH6-F

Application and Description

The cables are used for applications with medium mechanical stresses and sharp bending in one place.
They are suitable for use in dry, damp and wet rooms as power and control cable, especially on hoisting
equipment, handling systems, machine tools, etc.

Standard and Approval

<HAR>HD 359 S3, BS EN 50214, DIN VDE 0281 part 404, IEC 60332-1, CSA C22.2 N° 49, UL 62, UL 62

Cable Construction

- Fine bare or tinned copper strands
- Strands to VDE-0295 Class-5, IEC 60228 Class-5
- PVC compound insulation T12 to VDE 0207 part 4
- Color coded to VDE-0293-308
- PVC compound outer jacket TM2 to VDE 0207 part 5

Technical Characteristics

-Working voltage:
       H05VVH6-F : 300/500 V
       H07VVH6-F: 450/700 V
-Test voltage:
       H05VVH6-F : 2 KV
       H07VVH6-F: 2.5 KV
-Bending radius: 10 × cable Ø
-Flexing temperature: - 5º C to + 70º C
-Static temperature :-40º C to +70º C
-Flame retardant: test class B according to VDE 0472 part 804, IEC 60332-1
-Insulation resistance: 20 MΩ x km

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
H05VVH6-F
18(24/32)
4 x 0.75
1.2
0.6
4.2 x 12.6
29
90
18(24/32)
8x 0.75
1.2
0.6
4.2 x 23.2
58
175
18(24/32)
12x 0.75
1.2
0.6
4.2 x 33.8
86
260
18(24/32)
18x 0.75
1.2
0.6
4.2 x 50.2
130
380
18(24/32)
24x 0.75
1.2
0.6
4.2 x 65.6
172
490
17(32/32)
4 x 1.00
1.4
0.7
4.4 x 13.4
38
105
17(32/32)
5×1.00
1.4
0.7
4.4 x 15.5
48
120
17(32/32)
8 x 1.00
1.4
0.7
4.4 x 24.8
77
205
17(32/32)
12x 1.00
1.4
0.7
4.4 x 36.2
115
300
17(32/32)
18x 1.00
1.4
0.7
4.4 x 53.8
208
45
17(32/32)
24x 1.00
1.4
0.7
4.4 x 70.4
230
590
H07VVH6-F
16(30/30)
4 x1.5
1.5
0.8
5.1 x 14.8
130
58
16(30/30)
5 x1.5
1.5
0.8
5.1 x 17.7
158
72
16(30/30)
7 x1.5
1.5
0.8
5.1 x 25.2
223
101
16(30/30)
8 x1.5
1.5
0.8
5.1 x 27.3
245
115
16(30/30)
10 x1.5
1.5
0.8
5.1 x 33.9
304
144
16(30/30)
12 x1.5
1.5
0.8
5.1 x 40.5
365
173
16(30/30)
18 x1.5
1.5
0.8
6.1 x 61.4
628
259
16(30/30)
24 x1.5
1.5
0.8
5.1 x 83.0
820
346
14(30/50)
4 x2.5
1.9
0.8
5.8 x 18.1
192
96
14(30/50)
5 x2.5
1.9
0.8
5.8 x 21.6
248
120
14(30/50)
7 x2.5
1.9
0.8
5.8 x 31.7
336
168
14(30/50)
8 x2.5
1.9
0.8
5.8 x 33.7
368
192
14(30/50)
10 x2.5
1.9
0.8
5.8 x 42.6
515
240
14(30/50)
12 x2.5
1.9
0.8
5.8 x 49.5
545
288
14(30/50)
24 x2.5
1.9
0.8
5.8 x 102.0
1220
480
12(56/28)
4 x4
2.5
0.8
6.7 x 20.1
154
271
12(56/28)
5 x4
2.5
0.8
6.9 x 26.0
192
280
12(56/28)
7 x4
2.5
0.8
6.7 x 35.5
269
475
10(84/28)
4 x6
3.0
0.8
7.2 x 22.4
230
359
10(84/28)
5 x6
3.0
0.8
7.4 x 31.0
288
530
10(84/28)
7 x6
3.0
0.8
7.4 x 43.0
403
750
8(80/26)
4 x10
4.0
1.0
9.2 x 28.7
384
707
8(80/26)
5 x10
4.0
1.0
11.0 x 37.5
480
1120
6(128/26)
4 x16
5.6
1.0
11.1 x 35.1
614
838
6(128/26)
5 x16
5.6
1.0
11.2 x 43.5
768
1180