FAQ
30. EN 50382
Caledonian high temperature rolling stock cables conform to EN 50382 standard (The corresponding French
railway standard is NF F 63827) is characterized by its lightweight and small size which provide high flexibility
and easy handling required for high-speed train cable applications. High temperature cables imply higher current
capacity for the same cross- section. The higher the continuous temperature load, the longer the life time of the
cable at a given working temperature. Caledonian high temperature cable allow greater safety margins and
higher current capacity, with the following features:
Low weight cable
Low size cable
Thin wall cable
Wide operating temperature range (+125 °C down to -60 °C)
Low smoke density (>90% light transmission)
Short circuit cable and Earth fault-proof cables (>250 °C)
Conductors:
For 120 °C class : Flexible stranded tinned copper For 150 °C class : Flexible plain annealed copper Class 5 (or
class 6 on request) according to IEC 60228 with optional separator tape
Braiding:
Optional textile braid (for reinforced versions)
Insulation:
Type EI 111 or EI 112 (if sheathed) cross-linked halogen free silicone rubber
Sheathing:
Low temperature, oil resistant, ozone and UV resistant
For 120 °C class : special cross-linked black rubber type EM106 according to EN 50382-1
For 150 °C class : special cross-linked black silicone rubber type EM 107 according to EN 50382-1
Minimum Bending Radius: Dynamic use : 5 to 8 x outer diameter Static use : 4 x outer diameter
Standard:
EN 50382-1: General requirements applicable to cables, including detailed requirement for the insulating and
sheathing materials
High temperature rolling stock cables having special fire performance
N 50382-2 |
Single core, silicon rubber insulated cables for +120 °C and +150 °C |