Cables for Oil Industry | |||
Overall Screened & Armored Thermocouple Cable
Applications
These cables are used with thermocouples for temperature measurements where hydrocarbon may be present.
Standards
IEC 60584-3; NF C 42-324
Construction
Conductor:
Metal according to thermocouple type
Insulation:
PVC
Overall screen:
Aluminum/polyester tape with tinned copper drain wire
Inner sheath:
PVC
Armour:
Double steel tape
Sheath:
Special PVC. Color depends on thermocouple type
Properties
Flame retardance: NFC 32070 C2, IEC 60332-1-2
Operating voltage: 250V
Operating temperature: -20~60°C
Max. conductor temperature in service: 70°C
Chemical resistance: Aliphatic and aromatic hydrocarbon resistance
Conductor Size | No, of Pairs | Min. O.D. (mm) | Max. O.D. (mm) | Approx. Weight (kg/km) | |
---|---|---|---|---|---|
mm sq | Solid or Stranding | ||||
1 | 14 x 0.30 mm | 1 | 9.8 | 11.3 | 180 |
1.34 | 1 x 1.30 mm | 1 | 9.8 | 11.3 | 185 |
0.5 | 1 x 0.8 mm | 3 | 11.4 | 13.1 | 225 |
0.5 | 1 x 0.8 mm | 7 | 14.1 | 16.2 | 330 |
0.5 | 1 x 0.8 mm | 12 | 17.3 | 19.8 | 470 |
0.5 | 1 x 0.8 mm | 19 | 20.6 | 23.7 | 650 |
0.5 | 1 x 0.8 mm | 27 | 23.2 | 26.6 | 830 |