Coaxial Cables | ||||||||||||
CK 059/M2:RG59BX + 2 x 1.50mm2
Construction
Inner conductor1 | Copper covered steel(CCS) | 0.58mm |
---|---|---|
Dielectric | Lowdensity PE | Φ3.70±0.10mm |
Outer conductor(shield) | Plain copper | 180x0.10mm |
Shield coverage | 94% | |
Sheath | PVC | Φ6.20±0.10mm |
Inner conductor2 | Plain copper | 2x1.50mm2 |
Insulated cores2 | PVC | 2xΦ2.60±0.10mm |
Overall sheath | Φ11.490±0.30mm |
Electrical & Mechanical Characteristics
Impedance :75±5Ohm
Nominal capacitance :67pF/m
Velocity of propagation :66%
Insulation resistance :>2000Mohm.Km
Inner conductor resistance :158Ohm/Km
Outer conductor resistance :11Ohm/Km
Operating temperature range :-25°C-+80°C
Cores resistance :12Ohm/Km
Test/Operatig Voltage(max) :2KV/0.3KV
Copper weight :42.1Kg/Km
Cable weight(approx.) :186.9Kg/Km
Screening effectiveness :>55dB
Attenuation
Frequency(MHz) | Attenuation(dB/100m) | Attenuation(dB/100ft) |
---|---|---|
50 | 7.4 | 2.26 |
100 | 10.7 | 3.26 |
200 | 15.7 | 4.79 |
400 | 22.7 | 6.92 |
500 | 25.7 | 7.84 |
600 | 28.7 | 8.75 |
860 | 34.8 | 10.61 |
1000 | 38 | 11.59 |
Return Loss
30-300MHz | >31dB |
---|---|
300-600MHz | >28dB |
600-900MHz | >24dB |