IEC60092 Offshore & Marine Cables | |||
MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
MRE-M3GCH 150/250V Mica Tape + HEPR Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant
Instrumentation & Control Cables (Multipair)
Application
Marine cables are used on board of ships in all locations for fixed installations complying with IEC standards
60092-352 in safety circuit, where fire resistance is required. These cables are fire resistant, flame retardant,
low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels.
Standards
DIN 89159
IEC 60092-360/375
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1/2
IEC 61034
Construction
Conductors: Stranded copper conductor.
Insulation: Mica tape + HEPR.
Cabling Element: Pair.
Armour: Copper wire braid.
Outer Sheath: LSOH (SHF1).
Core Identification
Pair: White/blue with printed pair number and core number
Mechanical and Thermal PropertiesBending Radius for Fixed Installations: 6×OD
Temperature Range: -30℃ ~ +75℃
Dimensions and Weight
Part No. | Construction No. of elements×No. of cores in element×Cross section mm² |
Nominal Insulation Thickness mm |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
MRE-M3GCH-1P0.75 | 1×2×0.75 | 0.5 | 1.2 | 10.5 | 110 |
MRE-M3GCH-2P0.75 | 2×2×0.75* | 0.5 | 1.3 | 11.0 | 150 |
MRE-M3GCH-4P0.75 | 4×2×0.75 | 0.5 | 1.4 | 16.0 | 270 |
MRE-M3GCH-7P0.75 | 7×2×0.75 | 0.5 | 1.8 | 19.0 | 400 |
MRE-M3GCH-10P0.75 | 10×2×0.75 | 0.5 | 1.9 | 22.0 | 560 |
MRE-M3GCH-14P0.75 | 14×2×0.75 | 0.5 | 2.0 | 27.0 | 740 |
MRE-M3GCH-19P0.75 | 19×2×0.75 | 0.5 | 2.1 | 29.0 | 930 |
MRE-M3GCH-24P0.75 | 24×2×0.75 | 0.5 | 2.2 | 31.0 | 1110 |
*: 2 pairs are assembled as a quad.