IEC60092 Offshore & Marine Cables | |||
MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
UKOOA TYPE FM / TYPE FP 150/250V Fire Resistant
Application
Marine cables are designed for fixed installation for control and lighting in both and safe areas, emergency and
critical offshore applications where cable protection is required.
Standards
BS 6883/BS 7917/UKOOA
IEC 60331-21
IEC 60332-3-22 CAT. A
IEC 60332-1
IEC 60754-1 & IEC 60754-2
IEC 61034-1 & IEC 61034-2
Construction
Conductors:Stranded class 2 or flexible class 5 tinned annealed copper conductors to BS 6360/IEC 60228.
Fire Protection:Mica glass tape
Insulation: EPR complying with BS7655 GP4
Drain Wire:Tinned copper drain wire
Individual Screen:Aluminium mylar tape screen
Bedding:CSP – SW2 compound complying with BS 7655
Armour :Galvanised steel wire braid to BS 6883
Outer Sheath :CSP – SW2 compound complying with BS 7655 (TYPE FM: Blue; TYPE FP: Grey).
Dimensions and Weight
Construction No. of cores×Cross section |
Nominal Insulation Thickness |
Nominal Thickness of Inner Sheath |
Nominal Thickness of Outer Sheath |
Mominal Overall Diameter |
Approx. Weight |
mm² | mm | mm | mm | mm | kg/km |
3×2×0.75 | 0.8 | 1.2 | 1.4 | 18.6 | 580 |
7×2×0.75 | 0.8 | 1.4 | 1.6 | 23.2 | 915 |
12×2×0.75 | 0.8 | 1.6 | 1.8 | 29.7 | 1420 |
20×2×0.75 | 0.8 | 2.1 | 2.7 | 40.1 | 2905 |
3×3×0.75 | 0.8 | 1.3 | 1.5 | 20.4 | 700 |
7×3×0.75 | 0.8 | 1.5 | 1.7 | 26.6 | 1180 |
12×3×0.75 | 0.8 | 1.9 | 2.2 | 38.5 | 2550 |
1×4×0.75 | 0.8 | 1.2 | 1.3 | 14.6 | 360 |
1×2×1.0 | 0.8 | 1.0 | 1.2 | 13.0 | 295 |
1×3×1.0 | 0.8 | 1.0 | 1.2 | 13.6 | 330 |
1×4×1.0 | 0.8 | 1.0 | 1.3 | 15.9 | 380 |
3×2×1.5 | 0.8 | 1.3 | 1.4 | 21.6 | 732 |
7×2×1.5 | 0.8 | 1.4 | 1.6 | 27.8 | 1242 |
12×2×1.5 | 0.8 | 1.7 | 1.9 | 36.4 | 2039 |
3×3×1.5 | 0.8 | 1.3 | 1.5 | 24.5 | 780 |
7×3×1.5 | 0.8 | 1.5 | 1.7 | 32.1 | 1409 |
12×3×1.5 | 0.8 | 1.8 | 2.0 | 43.9 | 2301 |