Power Cables | ||||||||||||
|
Power Cables
BS 6622 Single Core Unarmoured (Copper Wire Screen) 15KV XLPE Stranded Copper Conductors
Construction
Cross-sectional area mm2 | Minimum average thickness of insulation mm | Nominal diameterover insulation mm |
Nominal area of copper wire screen mm2 |
Nominal thickness of PVC oversheath mm |
Nominal overall diameter of cable mm |
70 | 4.5 | 21.2 | 16 | 1.8 | 28.1 |
95 | 4.5 | 22.9 | 16 | 1.9 | 30.1 |
120 | 4.5 | 24.4 | 16 | 1.9 | 31.8 |
150 | 4.5 | 25.7 | 16 | 2 | 33.1 |
185 | 4.5 | 27.5 | 16 | 2 | 35.1 |
240 | 4.5 | 29.7 | 25 | 2.1 | 37.3 |
300 | 4.5 | 32.0 | 25 | 2.2 | 39.8 |
400 | 4.5 | 34.7 | 35 | 2.3 | 42.7 |
500 | 4.5 | 37.6 | 35 | 2.4 | 45.9 |
630 | 4.5 | 41.5 | 35 | 2.5 | 50.0 |
Installation
cross-sectional area mm2 | Approximate cable weight kg/m | Nominal drum length m |
Minimum bending radius mm | Nominal internal diameter of ducts mm |
70 | 0.9 | 1000 | 550 | 100 |
95 | 1.1 | 500 | 550 | 100 |
120 | 1.2 | 500 | 600 | 100 |
150 | 1.3 | 500 | 600 | 100 |
185 | 1.5 | 500 | 650 | 100 |
240 | 1.8 | 500 | 700 | 100 |
300 | 2 | 500 | 750 | 100 |
400 | 2.5 | 500 | 800 | 100 |
500 | 2.9 | 500 | 850 | 100 |
630 | 3.4 | 400 | 900 | 100 |
Electrical Performance
cross-sectional area mm2 | Maximum DC resistance of conductor at 20 ℃ uohms/m | Maximum AC resistance of conductor at 90 ℃ uohms/m | Reactance at 50Hz uohms/m |
Impedance at 50Hz uohms/m | Maximum Capacitace PF/m | Maximum charging current at normal voltage and frequency mA/m |
70 | 443.0 | 568 | 127 | 582 | 232 | 0.63 |
95 | 320.0 | 410 | 120 | 427 | 258 | 0.70 |
120 | 253.0 | 325 | 116 | 345 | 281 | 0.77 |
150 | 206.0 | 365 | 112 | 288 | 301 | 0.82 |
185 | 164.0 | 211 | 109 | 237 | 329 | 0.9 |
240 | 125.0 | 161 | 105 | 192 | 363 | 0.99 |
300 | 100.0 | 130 | 101 | 165 | 398 | 1.09 |
400 | 77.8 | 102 | 97.9 | 141 | 439 | 1.2 |
500 | 60.5 | 81 | 95.1 | 125 | 483 | 1.32 |
630 | 46.9 | 64 | 91.5 | 112 | 542 | 1.46 |
Ratings
Cross-sectional area mm2 |
Laid direct in ground Amps |
Drawn into ducts Amps |
Laid in air Amps |
One second short circuit rating of conductor KA |
One second short circuit rating of copper per core KA |
70 | 210 | 215 | 240 | 6.3 | 2.6 |
95 | 250 | 255 | 300 | 8.5 | 2.6 |
120 | 280 | 285 | 355 | 11 | 2.6 |
150 | 320 | 315 | 380 | 13.5 | 2.6 |
185 | 360 | 350 | 435 | 17 | 2.6 |
240 | 415 | 405 | 510 | 22.3 | 4.3 |
300 | 475 | 455 | 600 | 28 | 4.3 |
400 | 540 | 510 | 700 | 36.6 | 5.8 |
500 | 610 | 570 | 810 | 46.2 | 5.8 |
630 | 680 | 640 | 930 | 58.3 | 5.8 |