Railway Cables | ||||||
|
FRA 213D SW4
Applications :
-
These cables are designed for flexible installations, inside and outside railway rolling stock.
Standards :
-
DIN 5510-2
Construction :
-
Inner conductor:Stranded silver plated copper.
Insulation:Crosslink PE(PEX).
Outer conductor(shield1):Silver plated copper.
-
Outer conductor(shield2):Silver plated copper.
-
Sheath:LSZH Elastomer.
Electrical Characteristics at 20 °C :
Impedance | Ω | 50+/-2 |
Nomina lCapacitance | pF/m | 101 |
Minimum Insulation Resistance | MΩ.km | 100000 |
Inner Conductor Resistance | MΩ/km | 5.8 |
Outer Conductor Resistance | MΩ/km | 4.43 |
Attenuation | ||
@10MHz | dB/100m | 2 |
@50MHz | dB/100m | 5 |
@100MHz | dB/100m | 8 |
@150MHz | dB/100m | 10 |
@200MHz | dB/100m | 12 |
@300MHz | dB/100m | 15 |
@400MHz | dB/100m | 17 |
@450MHz | dB/100m | 19 |
@500MHz | dB/100m | 20 |
@600MHz | dB/100m | 22 |
@800MHz | dB/100m | 27 |
@850MHz | dB/100m | 28 |
@900MHz | dB/100m | 29 |
@950MHz | dB/100m | 30 |
@1000MHz | dB/100m | 31 |
@1800MHz | dB/100m | 45 |
@1900MHz | dB/100m | 47 |
@2000MHz | dB/100m | 49 |
@2400MHz | dB/100m | 55 |
@3000MHz | dB/100m | 64 |
@4000MHz | dB/100m | 79 |
@5000MHz | dB/100m | 93 |
@6000MHz | dB/100m | 106 |
Velocity of propagation | % | 66 |
Mechanical and Thermal Properties :
-
Minimum Bending Radius:50mm (static)
-
Temperature Range:-40℃~+105℃
Dimensions and Weight :
Conductor Construction No/mm | NominalInner Conductor Diameter mm | NominalOuter Conductor Diameter mm | NominalOverall Diameter mm | NominalWeight |
7/0.75 | 2.25 | 8.7 | 10.8 | 202 |