Railway Cables
Railway Signalling & Control Cables Railway Telecom Cables Railway Power & Control Cables FIRERAIL Traction Cables

 

MVB (Multifunction Vehicle Bus) Cables (Redundant Version)

 

Application

The cables are designed for permanent installation inside of rolling stock to connect fixed parts. A typical

application is a communication system in a locomotive. The system uses a wire backed bus system to the TCN

standard for control and instrumentation and for diagnostics. This bus system consists of the rail bus WTB

(Wired Train Bus) and the road bus MVB (Multifunction Vehicle Bus) which are connected via redundant

gateways.

Standards

DIN 5510-2

Construction

MVB (Multifunction Vehicle Bus) Cables (Redundant Version)

Conductors

Stranded tinned copper conductor according to IEC 60228 class 5.

Insulation

Foam skin-composite PE made of inner cellular layer and outer solid skin.

Core Wrapping

Plastic tape(s).

EMC Screen

Tinned copper braid.

Outer Sheath

Cross-linked oil resistant LSZH compound.

Electrical Characteristics at 20℃

Nominal Cross Section mm² 0.5
Maximum Conductor Resistance Ω/km 41
Impedance@0.75-3MHz Ω 120+/-12
Maximum Attenuation @1.5MHz dB/km 17
Maximum Attenuation @3MHz dB/km 25
Maximum Transfer Impedance mΩ/m 20
Nominal Voltage Rating V 300

Mechanical and Thermal Properties

Minimum Bending Radius:6×OD (single); 10×OD (multiple)

Temperature Range:-40℃ to +100℃ (during operation);

                                -20℃ +50℃ (during installation)

Dimensions And Weight

Cable Code No. of cores& Nominal
Conductor Cross
Sectional Area
No.×mm²
Nominal
Diameter of
Strands
No/mm
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
0.6 7.9 95
RD-MVB-02YSCH-1Q0.5S+4C0.25S 1×4×0.5+4×1×0.25 19/0.18 0.6 7.9 95