Railway Cables | ||||||||||
|
CCPSSP-FR0.1 n×4×0.9/1.4
Application
The cables are used as railway cables and can be installed directly into the ground or in ducts.
Standards
RENFE E.T. 03.365.051.6
Construction
Conductors: Soft annealed solid copper, 0.9/1.4 mm nominal diameter.
Insulation: PE insulation.
Cabling Element: Four insulated conductors are twisted together to form a quad.
Stranding: Quads are helically stranded in concentric layers.
Core Wrapping: Two or more layers of plastic tape(s) with overlapping.
Screen: 0.9/1.2/1.4/1.8mm copper wires wrapping with one plastic tape (protection against interference).
Inner Sheath: PE sheath.
Armour: Two layers of steel tape (0.8mm thick).
Outer Sheath: PE sheath.
Electrical Characteristics at 20℃
Nominal Conductor Diameter | mm |
0.9 |
1.4 |
Maximum Conductor Resistance | Ω/km |
28.5 |
11.7 |
Minimum Insulation Resistance @500 V DC | MΩ.km |
35000 |
35000 |
Mutual Capacitance @800Hz | nF/km |
41 |
45 |
Capacitance Unbalance @800Hz | |||
K1 maximum individual value | pF/460m |
250 |
250 |
K9-12 maximum individual value | pF/460m |
250 |
250 |
ea1/2 maximum individual value | pF/460m |
1200 |
1200 |
Attenuation | |||
@1KHz | dB/km |
0.7 |
0.46 |
@10KHz | dB/km |
1.6 |
0.85 |
@30KHz | dB/km |
2.1 |
1.3 |
Test Voltage @50Hz 1min | |||
Core to Core | Veff |
2100 |
2100 |
Core to Screen | Veff |
2500 |
2500 |
Core to Armouring | Veff |
2000 |
2000 |
Reduction Factor @100V/km 50Hz | 0.3 |
0.3 |
Mechanical and Thermal Properties
Minimum Bending Radius: 10×OD
Temperature Range: -40℃ to +60℃ (during operation);
-10℃ to +60℃ (during installation)
Dimensions And Weight
Cable Code | Number of Quads |
Nominal Sheath Thickness mm |
Maximum Overall Diameter mm |
Nominal Weight kg/km |
|
Inner |
Outer |
||||
0.9mm Conductor, 1.8mm Insulated Wire | |||||
RS/CCPSSP-FR0.1-2YD2YB2Y-1Q0.9 | 1 | 1.5 | 1.6 | 21.2 | 1140 |
RS/CCPSSP-FR0.1-2YD2YB2Y-3Q0.9 | 3 | 1.5 | 1.6 | 24.5 | 1370 |
RS/CCPSSP-FR0.1-2YD2YB2Y-5Q0.9 | 5 | 1.5 | 1.6 | 27.0 | 1610 |
RS/CCPSSP-FR0.1-2YD2YB2Y-7Q0.9 | 7 | 1.5 | 1.6 | 28.4 | 1750 |
RS/CCPSSP-FR0.1-2YD2YB2Y-10Q0.9 | 10 | 1.5 | 1.6 | 32.1 | 2060 |
RS/CCPSSP-FR0.1-2YD2YB2Y-12Q0.9 | 12 | 1.5 | 1.6 | 32.1 | 2130 |
RS/CCPSSP-FR0.1-2YD2YB2Y-14Q0.9 | 14 | 1.6 | 1.8 | 35.3 | 2380 |
RS/CCPSSP-FR0.1-2YD2YB2Y-19Q0.9 | 19 | 1.7 | 1.8 | 38.6 | 2760 |
RS/CCPSSP-FR0.1-2YD2YB2Y-25Q0.9 | 25 | 1.7 | 1.8 | 42.0 | 3150 |
1.4mm Conductor, 2.7mm Insulated Wire | |||||
RS/CCPSSP-FR0.1-2YD2YB2Y-1Q1.4 | 1 | 1.5 | 1.6 | 22.7 | 1280 |
RS/CCPSSP-FR0.1-2YD2YB2Y-3Q1.4 | 3 | 1.5 | 1.6 | 28.0 | 1690 |
RS/CCPSSP-FR0.1-2YD2YB2Y-5Q1.4 | 5 | 1.6 | 1.8 | 32.0 | 2070 |
RS/CCPSSP-FR0.1-2YD2YB2Y-7Q1.4 | 7 | 1.6 | 1.8 | 33.9 | 2320 |
RS/CCPSSP-FR0.1-2YD2YB2Y-10Q1.4 | 10 | 1.6 | 1.8 | 39.2 | 2860 |
RS/CCPSSP-FR0.1-2YD2YB2Y-12Q1.4 | 12 | 1.7 | 1.8 | 39.2 | 2980 |
RS/CCPSSP-FR0.1-2YD2YB2Y-14Q1.4 | 14 | 1.7 | 1.8 | 42.6 | 3340 |
RS/CCPSSP-FR0.1-2YD2YB2Y-19Q1.4 | 19 | 1.8 | 2.0 | 48.5 | 4160 |