CCPSSP-FR0.1 n×4×0.9/1.4

 

Application

The cables are used as railway cables and can be installed directly into the ground or in ducts.

Standards

RENFE E.T. 03.365.051.6

Construction

CCPSSP-FR0.1 n×4×0.9/1.4

Conductors: Soft annealed solid copper, 0.9/1.4 mm nominal diameter.

Insulation: PE insulation.

Cabling Element: Four insulated conductors are twisted together to form a quad.

Stranding: Quads are helically stranded in concentric layers.

Core Wrapping: Two or more layers of plastic tape(s) with overlapping.

Screen: 0.9/1.2/1.4/1.8mm copper wires wrapping with one plastic tape (protection against interference).

Inner Sheath: PE sheath.

Armour: Two layers of steel tape (0.8mm thick).

Outer Sheath: PE sheath.

Electrical Characteristics at 20℃

Nominal Conductor Diameter
mm
0.9
1.4
Maximum Conductor Resistance
Ω/km
28.5
11.7
Minimum Insulation Resistance @500 V DC
MΩ.km
35000
35000
Mutual Capacitance @800Hz
nF/km
41
45
Capacitance Unbalance @800Hz
K1 maximum individual value
pF/460m
250
250
K9-12 maximum individual value
pF/460m
250
250
ea1/2 maximum individual value
pF/460m
1200
1200
Attenuation
@1KHz
dB/km
0.7
0.46
@10KHz
dB/km
1.6
0.85
@30KHz
dB/km
2.1
1.3
Test Voltage @50Hz 1min
Core to Core
Veff
2100
2100
Core to Screen
Veff
2500
2500
Core to Armouring
Veff
2000
2000
Reduction Factor @100V/km 50Hz
0.3
0.3

Mechanical and Thermal Properties

Minimum Bending Radius: 10×OD

Temperature Range: -40℃ to +60℃ (during operation);

                                 -10℃ to +60℃ (during installation)

Dimensions And Weight

Cable Code
Number of
Quads
Nominal Sheath Thickness
mm
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
Inner
Outer
0.9mm Conductor, 1.8mm Insulated Wire
RS/CCPSSP-FR0.1-2YD2YB2Y-1Q0.9 1 1.5 1.6 21.2 1140
RS/CCPSSP-FR0.1-2YD2YB2Y-3Q0.9 3 1.5 1.6 24.5 1370
RS/CCPSSP-FR0.1-2YD2YB2Y-5Q0.9 5 1.5 1.6 27.0 1610
RS/CCPSSP-FR0.1-2YD2YB2Y-7Q0.9 7 1.5 1.6 28.4 1750
RS/CCPSSP-FR0.1-2YD2YB2Y-10Q0.9 10 1.5 1.6 32.1 2060
RS/CCPSSP-FR0.1-2YD2YB2Y-12Q0.9 12 1.5 1.6 32.1 2130
RS/CCPSSP-FR0.1-2YD2YB2Y-14Q0.9 14 1.6 1.8 35.3 2380
RS/CCPSSP-FR0.1-2YD2YB2Y-19Q0.9 19 1.7 1.8 38.6 2760
RS/CCPSSP-FR0.1-2YD2YB2Y-25Q0.9 25 1.7 1.8 42.0 3150
1.4mm Conductor, 2.7mm Insulated Wire
RS/CCPSSP-FR0.1-2YD2YB2Y-1Q1.4 1 1.5 1.6 22.7 1280
RS/CCPSSP-FR0.1-2YD2YB2Y-3Q1.4 3 1.5 1.6 28.0 1690
RS/CCPSSP-FR0.1-2YD2YB2Y-5Q1.4 5 1.6 1.8 32.0 2070
RS/CCPSSP-FR0.1-2YD2YB2Y-7Q1.4 7 1.6 1.8 33.9 2320
RS/CCPSSP-FR0.1-2YD2YB2Y-10Q1.4 10 1.6 1.8 39.2 2860
RS/CCPSSP-FR0.1-2YD2YB2Y-12Q1.4 12 1.7 1.8 39.2 2980
RS/CCPSSP-FR0.1-2YD2YB2Y-14Q1.4 14 1.7 1.8 42.6 3340
RS/CCPSSP-FR0.1-2YD2YB2Y-19Q1.4 19 1.8 2.0 48.5 4160