Railway Cables
Railway Signalling & Control Cables Railway Telecom Cables Railway Power & Control Cables FIRERAIL Traction Cables

 

CCPSSP-FR0.3 n×2×0.9/1.4

 

Application

The cables are used as railway cables and can be installed directly into the ground or in ducts.

Standards

RENFE E.T. 03.365.051.6

Construction

CCPSSP-FR0.3 n×2×0.9/1.4

Conductors: Soft annealed solid copper, 1.4 mm nominal diameter.

Insulation: PE insulation.

Cabling Element: Two insulated conductors are twisted together to form a pair.

Stranding: Pairs are helically stranded in concentric layers.

Core Wrapping: Two or more layers of plastic tape(s) with overlapping.

Screen: Copper tapes with overlap (protection against interference).

Inner Sheath: PE sheath.

Armour: Two layers steel tape (0.8mm thick).

Outer Sheath: PE sheath.

Electrical Characteristics at 20℃

Nominal Conductor Diameter mm 0.9 1.4
Maximum Conductor Resistance Ω/km 28.5 11.7
Minimum Insulation Resistance @500 V DC MΩ.km 15000 15000
Mutual Capacitance @1KHz nF/km 58 58
Capacitance Unbalance @1KHz
Pair to Pair pF/km 260 260
Pair to Earth pF/km 2625 2625
Test Voltage @50Hz 1min
Core to Core Veff 2100 2100
Core to Screen Veff 2500 2500
Reduction Factor @100V/km 50Hz 0.3 0.3

Mechanical and Thermal Properties

Minimum Bending Radius: 10×OD

Temperature Range: -40℃ to +60℃ (during operation);

                                  -10℃ to +60℃ (during installation)

Dimensions And Weight

Cable Code

Number of
Pairs

Nominal Sheath Thickness
mm

Maximum Overall
Diameter
mm

Nominal
Weight
kg/km

Inner

Outer

0.9mm Conductor, 1.8mm Insulated Wire

RS/CCPSSP-FR0.3-2Y(K)2YB2Y-6P0.9

6 1.5 1.6 19.2 720

RS/CCPSSP-FR0.3-2Y(K)2YB2Y-10P0.9

10 1.5 1.6 24.0 1011

RS/CCPSSP-FR0.3-2Y(K)2YB2Y-12P0.9

12 1.5 1.6 24.5 1067
1.4mm Conductor,2.7mm Insulated Wire

RS/CCPSSP-FR0.3-2Y(K)2YB2Y-2P1.4

2 1.5 1.6 22.5 904

RS/CCPSSP-FR0.3-2Y(K)2YB2Y-6P1.4

6 1.6 1.8 25.5 1155

RS/CCPSSP-FR0.3-2Y(K)2YB2Y-7P1.4

7 1.6 1.8 26.9 1258

RS/CCPSSP-FR0.3-2Y(K)2YB2Y-10P1.4

10 1.7 1.8 30.9 1542

RS/CCPSSP-FR0.3-2Y(K)2YB2Y-11P1.4

11 1.7 1.8 30.9 1576

RS/CCPSSP-FR0.3-2Y(K)2YB2Y-14P1.4

14 1.7 1.8 37.1 1827

RS/CCPSSP-FR0.3-2Y(K)2YB2Y-20P1.4

20 1.8 2.0 37.9 2214