Robotics

Extra Flex 10-42 Extra Flex S/H/R/F Extra Flex Flat/Armour

Robotics

Extra Flex F2-F3 F2 PVC-PVC F3 PETP-PUR

Type Code Formation Ext.Diam mm CU-weight kg/km
F2 F2CJ12RXC 3x(2x0.18)+6x0.8 9.5 83
F2 F2CJ16RXC 5x(2x0.18)+6x0.8 10.6 93
F3 F3CJ12RXC 3x(2x0.18)+6x0.8 8.6 81
F3 F3CJ16RXC 5x(2x0.18)+6x0.8 9.7 91

APPLICATION :

Supply of Fanuc brushless motors, Dynamic applications.

TECHNICAL CHARACTERISTICS :

Service Voltage :

300V

Test Voltage :

1500V

Insulation Resistance :

>/= 100 Mohm x km (at 20oC)

Capacitance :

abt. 100 pF/m at 20oC (cond. / cond.) abt. 150 pF/m (cond. / shield)

Temperature :

service from 0oC to +80oC, storage from -20oC to +80oC

Conductor Stranding :

flexible class 5 or 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29, tinned copper

Primary Insulation :

PETP polyester terephtalate

Conductors Identification :

3 x (2 x 0.18)mm2: (WHT-RD) + (WHT-BLK) + (RD-BLK) 5 x (2 x 0.18)mm2: as above +(WHT-GRN)+(GRN-BLK)6 x 0.8mm2: RD-RD-RD-BLK-BLK-BLK

Taping :

special tape

EMC Shield :

tinned copper braid covering >/= 85%

Jacket :

special PVC compound for type F2 polyurethane PUR abrasion-free for F3 colour black RAL 9005

Min. Bending Radius :

15 x ext. cable diameter for type F2 10 x ext. cable diameter for type F3 colour black RAL 9005

Translation Speed :

120 m/min. for type F2. 180 m/min. for type F3

Max. Acceleration :

4 m/s2 for type F2 7m/s2 for type F3

Reference Standards :

VDE 0472-804 C - IEC 332.3A - CEI 20-22 II for flame resistance for F2 type VDE 0472-804 B - IEC 332.1 - CEI

20-35 for flame resistance for F3 type VDE 0472-803-B ASTM2 oil resistance CNOMO E.03.40.150N - NFT 46-013

for resistance to industrial oils for F3