Airport Cable | |||
2491X to BS 6004 Cables
450/750V PVC Insulated, PVC Sheathed Electric Lock Cables (4 core)
FGD200 07VV-F (CU/PVC/PVC 450/750V Class 5)
APPLICATION
Airprot cables are multicore stranded flexible cables sheathed with thermoplastic PVC compound. The cables can
be offered with the ability to restrict the propagation of the flame in the event of a fire. This is especially
important to slow down the spreading of the fire as the cables may pass from one area to another within a
building. Applications can be found in control and power circuits, power stations, underground tunnels, lifts,
escalators, and high-rise buildings.
STANDARDS
Basic design to BS 6004, BS6500
FIRE PERFORMANCE
FlameRetardance (SingleVerticalWireTest)** | EN60332-1-2; IEC60332-1-2; BSEN 60332-1-2; VDE0482-332-1; NBN C30-004 (cat.F1);NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
---|---|
Reduced FirePropagation(Vertically-mountedbundledwires &cabletest)** | EN60332-3-24 (cat.C); IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBN C30-004 (cat.F2);NF C32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Note:
Asterisk * denotes superseded standard
Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC
compound and the cable design.
VOLTAGE RATING
450/750V
CABLE CONSTRUCTION
Conductor: Plain annealed copper wire, stranded according to BS 6360 Class 5
Insulation: PVC insulation type TI1 to BS 7655
Filler, binder (if any): PP, PET
Outer Sheath: PVC sheath type T6 to BS 7655
COLOUR CODE
Insulation Colour as per BS7671
withearth conductor | withoutearth conductor | |
---|---|---|
2Cores | - | Brown,Blue |
3Cores | Yellow/Green,Brown,Blue | Brown,Gray,Black |
4Cores | Yellow/Green,Brown,Gray,Black | Brown,Gray,Black,Blue |
5Cores | Yellow/Green,Brown,Gray,Black,Blue | Brown,Gray,Black,Blue,Black |
above 5 Cores | Yellow/Green,BlackNumbers | Black Numbers |
Outer sheath: Black or as order
Physical AND THERMAL PROPERTIES
Operating temperature: -15º C to +70º C
Short circuit temperature: +160º C
Minimum bending radius: 4x Overall Diameter
Insulation resistance: 20 MΩxkm
CONSTRUCTION PARAMETERS
Conductor | fGD20007VV-f | ||||||
---|---|---|---|---|---|---|---|
No.of CoreXCross Section |
No./ Nominal Diameterof Strands |
Conductor Diameter |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Max.DC resistance ofconductor @20°C | Approx. Weight |
Noxmm2 | No./mm | mm | mm | mm | mm | Ω/km | kg/km |
4x1.0 | 32/0.20 | 1.32 | 0.6 | 1.0 | 8.4 | 18.1 | 100 |
Electrical PROPERTIES
Conductor Operating Temperature : 90°C
Ambient Temperature : 30°C
Current-Carrying Capacities (Amp)
Conductor |
Reference |
Reference trunkingetc) |
Reference |
Reference |
Reference |
||
Horizontalflat spaced |
Verticalflat spaced |
Trefoil |
2cables, single- phase a.c.ord.c. |
3 or 4cables, 3-phasea.c. | 2 cables, single- phase a.c.ord.c |
3 or 4cables, 3-phasea.c. | 2cables, single- phase a.c.or d.c. flat andtouching |
3 or 4cables, 3-phase a.c. flat andtouching or trefoil |
2cables, single- phase a.c.or d.c.orflat and touching |
3 or 4cables, 3-phase a.c. flat andtouching or trefoil |
2cables, |
2cables, single- phase a.c.ord.c. or 3 cables three phase |
3
cables, trefoil 3-phasea.c. |
|
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
mm2 | A | A | A | A | A | A | A | A | A | A | A |
1.0 | 13 | - | - | - | 15 | - | - | - | - | - | - |
Voltage Drop (Per Amp Per Meter)
Nominal Cross Section Area |
2cables d.c. | 2cables, single-phasea.c. |
3or 4cables,3-phase a.c. | |||
---|---|---|---|---|---|---|
Ref.Methods3 and 4 (enclosedin conduitetc,inoron a wall) |
Ref.Methods1 and11 (clippeddirector ontray stouching) |
Ref.Methods3 and 4 (enclosedin conduitetc,inoron a wall) |
Ref.Methods1, | Ref.Methods 1and11 |
||
11 and12 (intrefoil) |
(Flat and touching) |
|||||
1 | 2 | 3 | 4 | 5 | 6 | 7 |
mm2 | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m |
1.0 | 46 | 46 | - | - | - | - |