Control Cables

IEC 60502 Type Cable

0.6/1 kV CVV-SWA

IEC 60502 (2-30 core)

Application : For use in duct, tray and for direct burying in ground. The cable subject to immerce in water all the

line.

Conductor : Concentric Stranded annealed copper wire

Insulation : PVC Black color

Identification : Printed White number on the surface of Black insulation

Filler : Suitable filler

Binding tape : Suitable tape

Inner sheath : PVC Black color

Armour : Galvanized steel wire

Binding tape : Suitable tape

Outher Sheath : PVC Black color

2 Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thickn
ess
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stan
dard Length
m
2 0.5 7/0.30 0.8 1.2 0.80 1.8 15.5 36.0 0.0162 320 500/D
0.75 7/0.37 0.8 1.2 0.80 1.8 15.5 24.5 0.0142 345 500/D
1 7/0.40 0.8 1.2 0.80 1.8 16.0 18.1 0.0135 350 500/D
1.5 7/0.50 0.8 1.2 0.80 1.8 16.5 12.1 0.0115 390 500/D
2.5 7/0.67 0.8 1.2 0.80 1.8 17.5 7.41 0.0093 460 500/D
4 7/0.85 1.0 1.2 1.25 1.8 21.0 4.61 0.0092 710 500/D
6 7/1.04 1.0 1.2 1.25 1.8 22.0 3.08 0.0078 820 500/D

3 Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thick
ness
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stan
dard Length
m
3 0.5 7/0.30 0.8 1.2 0.80 1.8 15.5 36.0 0.0162 365 500/D
0.75 7/0.37 0.8 1.2 0.80 1.8 16.0 24.5 0.0142 370 500/D
1 7/0.40 0.8 1.2 0.80 1.8 16.5 18.1 0.0135 385 500/D
1.5 7/0.50 0.8 1.2 0.80 1.8 17.0 12.1 0.0115 430 500/D
2.5 7/0.67 0.8 1.2 1.25 1.8 19.5 7.41 0.0093 635 500/D
4 7/0.85 1.0 1.2 1.25 1.8 21.5 4.61 0.0092 800 500/D
6 7/1.04 1.0 1.2 1.25 1.8 23.0 3.08 0.0078 935 500/D

4 Core CVV-SWA Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Diameter of steel wire armour
mm
Thick
ness of outer sheath mm
Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Stan
dard Length
m
4 0.5 7/0.30 0.8 1.2 0.80 1.8 16.5 36.0 0.0162 380 500/D
0.75 7/0.37 0.8 1.2 0.80 1.8 17.0 24.5 0.0142 410 500/D
1 7/0.40 0.8 1.2 0.80 1.8 17.0 18.1 0.0135 425 500/D
1.5 7/0.50 0.8 1.2 0.80 1.8 18.0 12.1 0.0115 480 500/D
2.5 7/0.67 0.8 1.2 1.25 1.8 20.5 7.41 0.0093 715 500/D
4 7/0.85 1.0 1.2 1.25 1.8 23.0 4.61 0.0092 915 500/D
6 7/1.04 1.0 1.2 1.25 1.8 24.5 3.08 0.0078 1075 500/D

5 Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thick
ness
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stand
ard Length
m
5 0.5 7/0.30 0.8 1.2 0.80 1.8 17.0 36.0 0.0162 420 500/D
0.75 7/0.37 0.8 1.2 0.80 1.8 18.0 24.5 0.0142 455 500/D
1 7/0.40 0.8 1.2 1.25 1.8 19.0 18.1 0.0135 595 500/D
1.5 7/0.50 0.8 1.2 1.25 1.8 20.0 12.1 0.0115 665 500/D
2.5 7/0.67 0.8 1.2 1.25 1.8 21.5 7.41 0.0093 805 500/D
4 7/0.85 1.0 1.2 1.25 1.8 24.5 4.61 0.0092 1040 500/D
6 7/1.04 1.0 1.2 1.60 1.8 27.0 3.08 0.0078 1385 500/D

6 Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thic
kness
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stan
dard Length
m
6 0.5 7/0.30 0.8 1.2 0.80 1.8 18.0 36.0 0.0162 450 500/D
0.75 7/0.37 0.8 1.2 1.25 1.8 19.5 24.5 0.0142 610 500/D
1 7/0.40 0.8 1.2 1.25 1.8 20.0 18.1 0.0135 635 500/D
1.5 7/0.50 0.8 1.2 1.25 1.8 21.0 12.1 0.0115 715 500/D
2.5 7/0.67 0.8 1.2 1.25 1.8 22.5 7.41 0.0093 870 500/D
4 7/0.85 1.0 1.2 1.60 1.8 26.5 4.61 0.0092 1270 500/D
6 7/1.04 1.0 1.2 1.60 1.8 28.5 3.08 0.0078 1515 500/D

7 Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thickn
ess
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stand
ard Length
m
7 0.5 7/0.30 0.8 1.2 0.80 1.8 18.0 36.0 0.0162 455 500/D
0.75 7/0.37 0.8 1.2 1.25 1.8 19.5 24.5 0.0142 620 500/D
1 7/0.40 0.8 1.2 1.25 1.8 20.0 18.1 0.0135 650 500/D
1.5 7/0.50 0.8 1.2 1.25 1.8 21.0 12.1 0.0115 730 500/D
2.5 7/0.67 0.8 1.2 1.25 1.8 22.5 7.41 0.0093 895 500/D
4 7/0.85 1.0 1.2 1.60 1.8 26.5 4.61 0.0092 1315 500/D
6 7/1.04 1.0 1.2 1.60 1.8 28.5 3.08 0.0078 1580 500/D

Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thick
ness
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stan
dard Length
m
8 0.5 7/0.30 0.8 1.2 1.25 1.8 20.0 36.0 0.0162 625 500/D
0.75 7/0.37 0.8 1.2 1.25 1.8 20.5 24.5 0.0142 680 500/D
1 7/0.40 0.8 1.2 1.25 1.8 21.0 18.1 0.0135 710 500/D
1.5 7/0.50 0.8 1.2 1.25 1.8 22.0 12.1 0.0115 810 500/D
2.5 7/0.67 0.8 1.2 1.25 1.8 24.0 7.41 0.0093 995 500/D
4 7/0.85 1.0 1.2 1.60 1.8 28.0 4.61 0.0092 1470 500/D
6 7/1.04 1.0 1.2 1.60 1.8 30.0 3.08 0.0078 1770 500/D

9 Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thick
ness
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stan
dard Length
m
9 0.5 7/0.30 0.8 1.2 1.25 1.8 20.5 36.0 0.0162 680 500/D
0.75 7/0.37 0.8 1.2 1.25 1.8 21.5 24.5 0.0142 750 500/D
1 7/0.40 0.8 1.2 1.25 1.8 22.0 18.1 0.0135 770 500/D
1.5 7/0.50 0.8 1.2 1.25 1.8 23.0 12.1 0.0115 885 500/D
2.5 7/0.67 0.8 1.2 1.60 1.8 26.0 7.41 0.0093 1230 500/D
4 7/0.85 1.0 1.2 1.60 1.8 29.5 4.61 0.0092 1630 500/D
6 7/1.04 1.0 1.2 1.60 1.9 32.0 3.08 0.0078 1975 500/D

10 Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thick
ness
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stan
dard Length
m
10 0.5 7/0.30 0.8 1.2 1.25 1.8 22.0 36.0 0.0162 725 500/D
0.75 7/0.37 0.8 1.2 1.25 1.8 22.5 24.5 0.0142 800 500/D
1 7/0.40 0.8 1.2 1.25 1.8 23.0 18.1 0.0135 835 500/D
1.5 7/0.50 0.8 1.2 1.25 1.8 24.5 12.1 0.0115 955 500/D
2.5 7/0.67 0.8 1.2 1.60 1.8 27.5 7.41 0.0093 1385 500/D
4 7/0.85 1.0 1.2 1.60 1.9 32.0 4.61 0.0092 1775 500/D
6 7/1.04 1.0 1.2 1.60 2.0 24.5 3.08 0.0078 2170 500/D

11 Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thick
ness
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stand
ard Length
m
11 0.5 7/0.30 0.8 1.2 1.25 1.8 22.0 36.0 0.0162 765 500/D
0.75 7/0.37 0.8 1.2 1.25 1.8 23.0 24.5 0.0142 840 500/D
1 7/0.40 0.8 1.2 1.25 1.8 23.5 18.1 0.0135 880 500/D
1.5 7/0.50 0.8 1.2 1.60 1.8 25.5 12.1 0.0115 1150 500/D
2.5 7/0.67 0.8 1.2 1.60 1.8 28.0 7.41 0.0093 1415 500/D
4 7/0.85 1.0 1.2 1.60 1.9 32.5 4.61 0.0092 1905 500/D
6 7/1.04 1.0 1.2 1.60 2.0 35.5 3.08 0.0078 2310 500/D

12 Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thick
ness
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stand
ard Length
m
12 0.5 7/0.30 0.8 1.2 1.25 1.8 22.0 36.0 0.0162 765 500/D
0.75 7/0.37 0.8 1.2 1.25 1.8 23.0 24.5 0.0142 845 500/D
1 7/0.40 0.8 1.2 1.25 1.8 23.5 18.1 0.0135 885 500/D
1.5 7/0.50 0.8 1.2 1.60 1.8 25.5 12.1 0.0115 1160 500/D
2.5 7/0.67 0.8 1.2 1.60 1.8 28.0 7.41 0.0093 1435 500/D
4 7/0.85 1.0 1.2 1.60 1.9 32.5 4.61 0.0092 1940 500/D
6 7/1.04 1.0 1.2 1.60 2.0 35.5 3.08 0.0078 2365 500/D

13 Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thick
ness
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stan
dard Length
m
13 0.5 7/0.30 0.8 1.2 1.25 1.8 23.0 36.0 0.0162 820 500/D
0.75 7/0.37 0.8 1.2 1.25 1.8 24.0 24.5 0.0142 905 500/D
1 7/0.40 0.8 1.2 1.25 1.8 24.5 18.1 0.0135 950 500/D
1.5 7/0.50 0.8 1.2 1.60 1.8 26.5 12.1 0.0115 1230 500/D
2.5 7/0.67 0.8 1.2 1.60 1.8 29.0 7.41 0.0093 1545 500/D
4 7/0.85 1.0 1.2 1.60 1.9 34.0 4.61 0.0092 2085 500/D
6 7/1.04 1.0 1.2 1.60 2.1 38.0 3.08 0.0078 2820 500/D

14 Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thic
kness
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stan
dard Length
m
14 0.5 7/0.30 0.8 1.2 1.25 1.8 23.0 36.0 0.0162 825 500/D
0.75 7/0.37 0.8 1.2 1.25 1.8 24.0 24.5 0.0142 915 500/D
1 7/0.40 0.8 1.2 1.25 1.8 24.5 18.1 0.0135 955 500/D
1.5 7/0.50 0.8 1.2 1.60 1.8 26.5 12.1 0.0115 1240 500/D
2.5 7/0.67 0.8 1.2 1.60 1.8 29.0 7.41 0.0093 1565 500/D
4 7/0.85 1.0 1.2 1.60 1.9 34.0 4.61 0.0092 2120 500/D
6 7/1.04 1.0 1.2 1.60 2.1 38.0 3.08 0.0078 2570 500/D

15 Core CVV-SWA Control Cable

No.of core Nominal
cross-sectional
area
sq.mm
No.&dia.
of wires
No./mm
Thickness
of insulation
mm
Thickness
of inner sheath
mm
Diameter of steel wire armour
mm
Thick
ness
of outer sheath
mm
Overall diameter (Approx.)
mm
Maximum
conductor
(at20C)
Ohm/km
Minimum
insulation resistance
(at70C)
Ohm/km
Cable weight (Approx.) kg/km Stand
ard Length
m
15 0.5 7/0.30 0.8 1.2 1.25 1.8 23.5 36.0 0.0162 880 500/D
0.75 7/0.37 0.8 1.2 1.60 1.8 25.5 24.5 0.0142 1115 500/D
1 7/0.40 0.8 1.2 1.60 1.8 26.0 18.1 0.0135 1150 500/D
1.5 7/0.50 0.8 1.2 1.60 1.8 27.5 12.1 0.0115 1330 500/D
2.5 7/0.67 0.8 1.2 1.60 1.8 30.0 7.41 0.0093 1675 500/D
4 7/0.85 1.0 1.2 1.60 2.0 35.5 4.61 0.0092 2305 500/D
6 7/1.04 1.0 1.2 2.00 2.1 39.5 3.08 0.0078 3085 500/D

16 Core CVV-SWA Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Diameter of steel wire armour
mm
Thick
ness of outer sheath mm
Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Stan
dard Length
m
16 0.5 7/0.30 0.8 1.2 1.25 1.8 23.5 36.0 0.0162 885 500/D
0.75 7/0.37 0.8 1.2 1.60 1.8 25.5 24.5 0.0142 1225 500/D
1 7/0.40 0.8 1.2 1.60 1.8 26.5 18.1 0.0135 1160 500/D
1.5 7/0.50 0.8 1.2 1.60 1.8 27.5 12.1 0.0115 1345 500/D
2.5 7/0.67 0.8 1.2 1.60 1.8 30.0 7.41 0.0093 1700 500/D
4 7/0.85 1.0 1.2 1.60 2.0 35.5 4.61 0.0092 2340 500/D
6 7/1.04 1.0 1.2 2.00 2.1 39.5 3.08 0.0078 3135 500/D

The table of 0.6/1 KV CVV-SWA shown concentric stranded conductor only
If you want to have solid or flexible conductor type, please contact with our Sales Department.

                                >>Return                                                     next>>