Industrial Cables  
H03VV-F H05VV-F H07RN-F more

Cathodic Protection Power Cable

KYNAR/HMWPE Cathodic Protection Power Cable

Application and Description

KYNAR/HMWPE Cathodic Protection Power Cable cable for use in deep anode groundbed installations, designed

to withstand corrosive gases.

Standard and Approval

ASTM specifications D-1248

Cable Construction

Conductor: Stranded bare copper conductor conforms to ASTM Specification B-8.

Insulation: A homogeneous wall of natural PVDF fluoropolymer (Kynar) shall be extruded over the conductor.

Jacket: Insulation is high molecular weight polyethylene conforming to ASTM-D-1248, Type 1, Class A, Category

5, Grades E4 and E5. Tensile Strengths J1, J3 available.

Technical Characteristics

Working voltage: 600V

Operating temperature: 150º C

Cable Parameter

 

Conductor Size
No. of Stranding
Circular Mils
AWG Diameter
In
Kynar Thickness
In
HMWPE Thickness
In
Nominal Outer Diameter
In
Total weight
Lbs/Mft
8 AWG 7 16.51 0.146 0.02 0.065 0.316 83
6 AWG 7 26.24 0.184 0.02 0.065 0.354 120
4 AWG 7 41.74 0.232 0.02 0.065 0.402 177
2 AWG 7 66.36 0.283 0.02 0.065 0.462 260