Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial 

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  High Temperature Cables 

High Temperature Cables

Multicore Silicone insulated & sheathed SIHF Cables

Application :
These cables are suitable in in the bad environment such as high temperature, low temperature, acid, alkali, oil. The max operation temperature of cable conductor is 180°C,

Conductors: Flexible tinned annealed copper

Conductor Stranding: Class 5 flexible

Insulation: SIF (Silicone rubber)

Conductor identification: 2 core: brown & blue, 3 core: brown, blue & green/yellow 4 core: brown, blue, black & green/yellow, 5 core brown, blue, 2 black & green/yellow

Sheath/Jacket: SIF (silicon rubber)

Voltage: 300/500V

Operating temperature: Maximum 180°C. minimum -60°C

Minimum Bending Radius: 5 x overall diameter

Standards: VDE0295: Conductors of cables, wires and flexible cords for power installations

Size sq
(mm)

No. of cores
(mm)
Diameter over laid up cores
(mm)
Nominal Overall Diameter
(mm)

Weight
(Kg/Km)

0.75

2
4.8
6.4

54

1.0

2
5.0
6.7

60

1.5
2
5.6
7.6

82

2.5

2
6.8
9.3

136

4

2
8.4
10.8

182

6
2
9.8
12.2

275

0.75

3
5.2
6.8

64

1.0

3
5.4
7.5

79

1.5
3
6.0
8.0

99

2.5

3
7.3
9.7

153

4

3
9.1
11.5

224

6
3
10.6
13.0
339
10
3
14.5
17.3
533
0.75
4
5.8
7.8
84
1.0
4
6.1
8.1
95
1.5
4
6.8
8.8
123
2.5
4
8.2
10.7
189
4
4
10.2
12.5
295
6
4
11.9
14.2
443
10
4
16.2
19.8
708
16
4
20.0
24.0
1015
0.75
5
6.5
8.5
102
1.0
5
6.8
8.9
117
1.5
5
7.6
9.6
148
2.5
5
9.2
11.7
230
4
5
11.3
14.4
361
6
5
13.2
16.2
536
10
5
18.1
21.7
882
0.75
7
7.2
9.2
125
1.0
7
7.5
9.6
144
1.5
7
8.4
10.4
188
2.5
7
10.2
12.7
194
0.75
8
8.8
11.0
145
1.0
8
9.2
11.6
176
1.5
8
10.2
12.6
226
2.5
8
12.4
15.0
342
0.75
10
9.6
12.0
179
1.0
10
10.0
12.4
210
1.5
10
11.2
13.6
272
2.5
10
13.6
16.2
415
0.75
12
10.0
12.4
205
1.0
12
10.4
12.8
242
1.5
12
11.6
14.2
322
2.5
12
14.1
16.9
492

Current-Carrying Capacity (amperes): and Mass Supportable (Kg):

Conductor
cross-sectional area
Current carrying capacity

Max mass suporatble by twin flexible cord

Single phase a.c.
Three phase a.c.

(mm)

(A)
(A)

(Kg)

0.5
3
3

2

0.75

6
6

3

1

10
10

5

1.25
13
-

5

1.5

16
16

5

2.5

25
20

5

4
32
25

5