Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial 

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Cable Instrumentación 

Cable Instrumentación

1. ESI 0.9-6(1-0.8)

Constructional & Electrical Performance Data
ESI 09-6 Issue 6 Section 3 – Induced Voltage Control Cable

Conductores
0.80mm Plain annealed copper wire in accordance with BS6360 Class 1.
Aislamiento
The conductors are insulated with Polyvinyl Chloride Type 02 to BS7655, uniformly twisted together to form a pair with a
maximum lay length of 125mm, and colour coded for identification (See Table 1). Suitable for voltages upto and including
150 Volts (d.c.) and 110 Volts (a.c.)
Cable Formación
2 pair cables are laid up in quad formation.
5 – 10 pair cables are laid up in layer formation.
20 – 200 pairs cables are laid up in 20 pair units to form the required cable size. A printed number on a longitudinal tape
applied under the binder tape identifies each unit.
Pantallas
For 2 pair cables the screen comprises of an aluminium foil in contact with a 0.80mm tinned copper drain wire. For 5 pairs and
above the screen comprises of an aluminium tape with a backing that ensures adhesion to the bedding. The tape screen is
applied over a ripcord and in contact with a 0.80mm tinned copper drain wire.

Note: Armoured cables (Generation) always require a collective screen. Types 1 & 2 can incorporate a
screen if required.
Cubiertas exteriores

Type 1

Unarmoured Multipair Light Current Control cables.
Extruded Polyvinyl Chloride sheath to BS7655.

Type 2

Armoured Multipair Light Current Control cables.
Extruded Polyvinyl Chloride bedding to BS7655, Galvanised steel wire armour to BS1442 and an extruded
Polyvinyl Chloride sheath to BS7655.

Type 3

Armoured Multipair (Generation) Light Current Control cables.
Extruded Polyvinyl Chloride bedding to BS7655, Galvanised steel wire armour to BS1442 (2 – 10 pair)
Galvanised steel tape armour (20 – 200 pair) and an extruded Polyvinyl Chloride sheath to BS7655.

Alternative PVC materials producing lower levels of HCL are available on request.

Características Eléctricas

Los ensayos de Alta Tensión

Colectiva pantallas

2000 Volts for 1 minute between each conductors & earth
5000 Volts for 1 minute between all conductors & earth

Cables sin pantalla

10 000 Volts (ac) for 1 minute between each conductor & earth
15 000 Volts (ac) for 1 minute between all conductors bunched & earth

Conductor de Resistencia

73.60Ohm/Km Loop @ 20°C (Max)

De resistencia de aislamiento

80 Mohm/Km @ 20°C (Min)

Desequilibrio Capacitancia

2 Pair
above 2 Pair

800 pF/500 mtrs @ 1 kHz (Max)
400 pF/500 mtrs @ 1 kHz (Max)

Capacitancia mutua

Mutual Capacitance

Inductancia mutua

915 μH/500 mtrs @ 1 kHz (Max)

Cable Dimensiones & Identificación


Type 1 cables ( Unarmored, Induced voltages up to 5kV)
Type 2 cables (Armoured)
Type 3 cables (Generation)

    <<ESI 0.9-6(1-0.9)