Parámetros de ensayo |
EIA/TIA-455 FOTP Number |
IEC-794-1 Test Method |
EN 187000Test Method |
El aumento de la pérdida máxima |
Tensile Load & Bending |
33 |
E1 |
501 |
<0.05dB (90%); <0.15dB (100%) |
Baja & HighTemperature Bend |
37 |
E11 |
|
<0.05dB (90%); <0.15dB (100%) |
La compresión de carga (Crush) |
41 |
E3 |
504 |
<0.05dB (90%); <0.15dB (100%) 440N/km(250lb/in) load |
Resistencia al impacto |
25 |
E4 |
505 |
<0.05dB (90%); <0.15dB (100%) |
Twist (Torson) |
85 |
E7 |
508 |
<0.05dB (90%); <0.15dB (100%) |
Cíclica flexión (Bending repetida) |
104 |
E6 |
509 |
<0.05dB (90%); <0.15dB (100%) |
Exteriores congelación |
98 |
F6 |
|
<0.05dB (90%); <0.15dB (100%) |
Temperatura Ciclismo |
3 |
F1 |
601 |
<0.05dB (90%); <0.15dB (100%) |
Fibra Stripability |
178 |
B6 |
|
<8.9N(2lbf) on unaged and aged fi ber; >1.3N(0.3lbf) on unaged and aged fi ber |
Cable Envejecimiento |
82 |
F5 |
|
<0.1dB (90%); <0.25dB (100%) |
La penetración del agua |
82 |
F5 |
|
No flow after 24 hours from 1 meter length of cable |
Compuesto de flujo (Drip) |
81 |
E14 |
|
80 C 24 hrs duration, no drip |
Parámetros de ensayo |
EIA/TIA-455 FOTP Number |
IEC-794-1 Test Method |
EN 187000 Test |
MethodMaximum Increased loss |
De carga y tracción Bending |
33 |
E1 |
501 |
<0.2dB |
Baja & HighTemperature Bend |
37 |
E11 |
|
<0.4dB |
La compresión de carga (Crush) |
41 |
E3 |
504 |
<0.2dB 440N/km(250lb/in) load |
Cíclica de impacto |
25 |
E4 |
505 |
<0.4dB |
Twist (torsión) |
85 |
E7 |
508 |
<0.2dB |
Cíclica flexión (Bending repetida) |
104 |
E6 |
509 |
<0.2dB |
Exteriores congelación |
98 |
F6 |
|
<0.2dB |
Temperatura Ciclismo |
3 |
F1 |
601 |
<0.05dB (90%); <0.15dB (100%) |
Fibra Stripability |
178 |
B6 |
|
<13.4N(3lbf) on unaged fi ber |
Cable Envejecimiento |
82 |
F5 |
|
<0.1dB (90%); <0.25dB (100%) |
La penetración del agua |
82 |
F5 |
|
No flow after 24 hours from 1 meter length of cable |
Compuesto de flujo (por goteo) |
81 |
E14 |
|
80 C 24 hrs duration, no drip |