Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial 

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H03VV-F/H03VVH2-F

Application and Description

These cable types are especially suited for use on small appliances with low mechanical stress and for
connection for light household appliances, e.g. kitchen utensils, desk lamps, floor lamps, vacuum cleaners,
office machines, radios, etc. As far as these cables are admitted to the relevant specifications of the
equipment, They are not permitted for use with cooking or heating apparatus. Cables with cross section 0.75
mm² are not suitable for outdoor use or use of industrial or farmer machineries. Max operating voltage in
single or three phase system is Uo/U 330/330 volts. In a direct current system max operating voltage is Uo/U
495/495 volts.

Standard and Approval

<HAR>BS6500, CENELEC HD21.5, VDE 0281, CEI 20-20/5, CEI 20-35 (EN60332-1), CEI 20-52,
CE low voltage directive 73/23/EEC & 93/68/EEC.ROHS compliant

Cable Construction

- Bare copper fine wire conductor
- Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383
- PVC core insulation T12 to VDE-0281 Part 1
- Color coded to VDE-0293-308
- Green-yellow grounding (3 conductors and above)
- PVC outer jacket TM2

            

Technical Characteristics

- Working voltage: 300/300 volts
- Test voltage: 2000 volts
- Flexing bending radius: 7.5 x Ø
- Static bending radius: 4 x Ø
- Flexing temperature: -5º C to +70º C
- Static temperature: -40º C to +70º C
- Short circuit temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km

         

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
H03VV-F
20(16/32)
2 x 0.50
0.5
0.6
5
9.6
38
20(16/32)
3 x 0.50
0.5
0.6
5.4
14.4
45
20(16/32)
4 x 0.50
0.5
0.6
5.8
19.2
55
18(24/32)
2 x 0.75
0.5
0.6
5.5
14.4
46
18(24/32)
3 x 0.75
0.5
0.6
6
21.6
59
18(24/32)
0.5
0.6
6.5
28.8
72
18(24/32)
5 x 0.75
0.5
0.6
7.1
36.0
87
H03VVH2-F
20(16/32)
2 x 0.50
0.5
0.6
3.2 x 5.2
9.7
32
18(24/32)
2 x 0.75
0.5
0.6
3.4 x 5.6
14.4
35