Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial 

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05V2-K/H07V2-K

Application and Description

These special heat-resistant flexible single-conductor hook-up wires are ideal for use in power current
installation, switch cabinets, motors and transformers which are subject to direct contact with high
temperature (e.g. varnishing machines and drying towers etc.). These are also suitable for inside wiring of
electrical equipments such as lighting and heating apparatus.

Standard and Approval

<HAR> HD 21.7 S2, CEI 20-20, CEI20-52, VDE-0281 Part-7,
CE Low Voltage Directive 73/23/EEC and 93/68/EEC,ROHS compliant

Cable Construction

- Fine bare copper strands
- Strands to VDE-0295 Class-5, IEC 60228 Class-5, BS 6360 cl. 5 and HD 383
- Special heat resistant PVC TI3 core insulation to DIN VDE 0281 part 7
- Cores to VDE-0293 colors
- H05V2-K (20, 18 & 17 AWG)
- H07V2-K (16 AWG and Larger)

Technical Characteristics

- Working voltage: 300/500v (H05V2-K)/ 450/750v (H07V2-K)
- Working voltage: - Test voltage: 2000 volts
- Flexing bending radius: 10-15 x Ø
- Static bending radius: 10-15 x Ø
- Flexing temperature: +5º C to +90º C
- Static temperature: -10º C to +105º C
-Short circuit temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km

          

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Overall Diameter
mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
H05V2-K
20(16/32)
1 x 0.5
0.6
2.5
4.8
8.7
18(24/32)
1 x 0.75
0.6
2.7
7.2
11.9
17(32/32)
1 x 1
0.6
2.8
9.6
14.0
H07V2-K
16(30/30)
1 x 1.5
0,7
3.4
14.4
20
14(50/30)
1 x 2.5
0,8
4.1
24
33.3
12(56/28)
1 x 4
0,8
4.8
38
48.3
10(84/28)
1 x 6
0,8
5.3
58
68.5
8(80/26)
1 x 10
1,0
6.8
96
115
6(128/26)
1 x 16
1,0
8.1
154
170
4 (200/26)
1 x 25
1,2
10.2
240
270
2 (280/26)
1 x 35
1,2
11.7
336
367
1 (400/26)
1 x 50
1,4
13.9
480
520
2/0 (356/24)
1 x 70
1,4
16
672
729
3/0 (485/24)
1 x 95
1,6
18.2
912
962
4/0 (614/24)
1 x 120
1,6
20.2
1115
1235
300 MCM(765/24)
1 x 150
1,8
22.5
1440
1523
350 MCM(944/24)
1 x 185
2,0
24.9
1776
1850
500MCM(1225/24)
1 x 240
2,2
28.4
2304
2430