Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial 

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05V2-U/H07V2-U

Application and Description

These cables are for fixed protected installation inside appliances and in, or on, lighting fittings. Suitable
for installation in surface mounted or embedded conduits, only for signalling and control circuits. Maximum
conductor temperature in normal use 90°C. Not to be used in contact with object higher then 85°C. Not
suitable for fixed distribution system.

Standard and Approval

<HAR> HD 21.7 S2, VDE-0281 Part-7, CEI20-20/7,
CE Low Voltage Directive 73/23/EEC and 93/68/EEC, ROHS compliant

Cable Construction

- Solid bare copper single wire
- Solid to DIN VDE 0281-3, HD 21.3 S3 and IEC 60227-3
- Special PVC TI3 ore insulation
- Cores to VDE-0293 colors on chart
- H05V-U (20, 18 & 17 AWG)
- H07V-U (16 AWG and Larger)

Technical Characteristics

- Working voltage: 300/500v (H05V-U)
- Working voltage: 450/750v (H07V-U)
- Test voltage: 2000V(H05V-U)/2500V (H07V-U)
- Flexing bending radius: 15 x Ø
- Static bending radius: 15 x Ø
- Flexing temperature: -5º C to +70º C
- Static temperature: -30º C to +80º C
- Short circuit temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 10 MΩ x km

           

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Overall Diameter
mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
20
1 x 0.5
0.6
2.1
4.8
9
18
1 x 0.75
0.6
2.2
7.2
11
17
1 x 1
0.6
2.4
9.6
14
16
1 x 1.5
0.7
2.9
14.4
21
14
1 x 2.5
0.8
3.5
24.0
33
12
1 x 4
0.8
3.9
38.0
49
10
1 x 6
0.8
4.5
58.0
69
8
1 x 10
1.0
5.7
96.0
115