Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial 

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05VV-F/H05VVH2-F

Application and Description

These cables are suited for medium mechanical stress in damp and wet environments such as refrigerators,
washing machines, spin dryers and other appliances, as long as it meets applicable equipment
specifications. These cables are also suited for cooking and heating apparatus, provided that the cable
does not come into direct contact with the hot parts of the apparatus or with any other heat source. Further
applications of this cable include: Fixed installation in furniture, partition walls, decorative covering, and in
the hollow spaces of prefabricated building parts. They are not suitable for outdoor use, industrial (except
clothing manufacture) or farming applications. Max operating voltage in single or three phase system is Uo/U
318/550 volts. In a direct system, max operating voltage is Uo/U 413/825 volts.

Standard and Approval

<HAR>CEI 20-20/5 / 20-35 (EN60332-1) /20-52,
0.5 - 2.5mm² to BS6500, 4.0mm² to BS7919, 6.0mm² generally to BS7919,
VDE0281, CENELEC HD21.5, CE low voltage directive 73/23/EEC & 93/68/EEC., ROHS compliant

Cable Construction

- Bare copper fine wire conductor
- Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383
- PVC core insulation T12 to VDE-0281 Part 1
- Color coded to VDE-0293-308
- Green-yellow grounding (3 conductors and above)
- PVC outer jacket TM2

         

Technical Characteristics

- Working voltage: 300/500 volts
- Test voltage: 2000 volts
- Flexing bending radius: 7.5 x Ø
- Static bending radius: 4 x Ø
- Flexing temperature: -5º C to +70º C
- Static temperature: -40º C to +70º C
- Short circuit temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km

          

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
H05VV-F
18(24/32)
2 x 0.75
0.6
0.8
6.4
14.4
57
18(24/32)
3 x 0.75
0.6
6.8
21.6
68
18(24/32)
4 x 0.75
0.6
0.8
7.4
29
84
18(24/32)
5 x 0.75
0.6
0.9
8.5
36
106
2 x 1.00
0.6
0.8
6.8
19
65
17(32/32)
3 x 1.00
0.6
0.8
7.2
29
79
17(32/32)
4 x 1.00
0.6
0.9
8.0
38
101
17(32/32)
5 x 1.00
0.6
0.9
8.8
48
123
16(30/30)
2 x 1.50
0.7
0.8
7.6
29
87
16(30/30)
3 x 1.50
0.7
0.9
8.2
43
111
16(30/30)
4 x 1.50
0.7
1.0
9.2
58
142
16(30/30)
5 x 1.50
0.7
1.1
10.5
72
176
14(30/50)
2 x 2.50
0.8
9.2
48
134
14(30/50)
3 x 2.50
0.8
1.1
10.1
72
169
14(30/50)
4 x 2.50
0.8
1.1
11.2
96
211
14(30/50)
5 x 2.50
0.8
1.2
12.4
120
262
12(56/28)
3 x 4.00
0.8
1.2
11.3
115
233
12(56/28)
4 x 4.00
0.8
1.2
12.5
154
292
12(56/28)
5 x 4.00
0.8
1.4
13.7
192
369
3 x 6.00
0.8
1.1
13.1
181
328
10(84/28)
4 x 6.00
0.8
1.3
13.9
230
490
H05VVH2-F
18(24/32)
2 x 0.75
0.6
0.8
4.2 x 6.8
14.4
48
17(32/32)
2 x 1.00
0.6
0.8
4.4 x 7.2
19.2
57