Cables for Oil Industry

 Overall Screened Thermocouple Cable

Cables for Oil Industry

Applications

These cables are used with thermocouples for temperature measurements where hydrocarbon may be present.

Standards

IEC 60584-3; NF C 42-324

Construction

Conductor:

Metal according to thermocouple type

Insulation:

PVC

Overall screen:

Aluminum/polyester tape with tinned copper drain wire

Sheath:

Special PVC. Color depends on thermocouple type

Properties

Flame retardance: NFC 32070 C2, IEC 60332-1-2

Operating voltage: 250V

Operating temperature: -20~60°C

Max. conductor temperature in service: 70°C

Chemical resistance: Aliphatic and aromatic hydrocarbon resistance

Conductor Size No, of Pairs Min. O.D. (mm) Max. O.D. (mm) Approx. Weight (kg/km)
 mm sq Solid or Stranding
1 14 x 0.30 mm 1 6.3 7.4 70
1.34 1 x 1.30 mm 1 6.3 7.4 75
0.5 1 x 0.8 mm 3 8.0 9.3 95
0.5 1 x 0.8 mm 7 10.5 12.1 165
0.5 1 x 0.8 mm 12 13.3 15.3 255
0.5 1 x 0.8 mm 19 16.5 19.0 380
0.5 1 x 0.8 mm 27 19.2 22.0 510