Single Core Cables having PVC Insulation, Unarmoured, With or Without Sheath (Copper Conductor)
450/750V or 600/1000V Current-Carrying Capacities (Amp) PVC & PVC/PVC Cables
Reference Method 4 (Enclosed in conduit in thermally insulating wall etc) | Reference Method 3 (Enclosed in conduit on a wall or in trunking etc) | Reference Method 1 (Clipped direct) | Reference Method 11 (on a perforated cable tray horizontal or vertical) | Reference Method 12 (free air) | ||||||||
Horizontal flat spaced | Vertical flat spaced | Trefoil | ||||||||||
Conductor cross-sectional area (mm²) | 2 cables single-phase ac or dc (Amp) | 3 or 4 cables 3-phase ac (Amp) | 2 cables single-phase ac or dc (Amp) | 3 or 4 cables 3-phase ac (Amp) | 2 cables single-phase ac or dc (Amp) | 3 or 4 cables 3-phase ac (Amp) | 2 cables single-phase ac or dc or flat and touching (Amp) | 3 cables 3-phase ac flat and touching (Amp) | 2 cables single-phase ac or dc or 3 cables or trefoil (Amp) | 2 cables single-phase ac or dc or 3 cables 3-phase ac (Amp) | 3 cables trefoil 3-phase ac (Amp) | |
BS 6004 | 1 | 11 | 10.5 | 13.5 | 12 | 15.5 | 14 | - | - | - | - | - |
1.5 | 14.5 | 13.5 | 17.5 | 15.5 | 20 | 18 | - | - | - | - | - | |
2.5 | 19.5 | 18 | 24 | 21 | 27 | 25 | - | - | - | - | - | |
4 | 26 | 24 | 32 | 28 | 37 | 33 | - | - | - | - | - | |
6 | 34 | 31 | 41 | 36 | 47 | 43 | - | - | - | - | - | |
10 | 46 | 42 | 57 | 50 | 65 | 59 | - | - | - | - | - | |
16 | 61 | 56 | 76 | 68 | 87 | 79 | - | - | - | - | - | |
25 | 80 | 73 | 101 | 89 | 114 | 104 | 126 | 112 | 146 | 130 | 110 | |
35 | 99 | 89 | 125 | 110 | 141 | 129 | 156 | 141 | 181 | 162 | 137 | |
BS 6346 | 50 | 119 | 108 | 151 | 134 | 182 | 167 | 191 | 172 | 219 | 197 | 167 |
70 | 151 | 136 | 192 | 171 | 234 | 214 | 246 | 223 | 281 | 254 | 216 | |
95 | 182 | 164 | 232 | 207 | 284 | 261 | 300 | 273 | 341 | 311 | 264 | |
120 | 210 | 188 | 269 | 239 | 330 | 303 | 349 | 318 | 396 | 362 | 308 | |
150 | 240 | 216 | 300 | 262 | 381 | 349 | 404 | 369 | 456 | 419 | 356 | |
185 | 273 | 245 | 341 | 296 | 436 | 400 | 463 | 424 | 521 | 480 | 409 | |
240 | 320 | 286 | 400 | 346 | 515 | 472 | 549 | 504 | 615 | 569 | 485 | |
300 | 367 | 328 | 458 | 394 | 594 | 545 | 635 | 584 | 709 | 659 | 561 | |
400 | - | - | 546 | 467 | 694 | 634 | 732 | 679 | 852 | 795 | 656 | |
500 | - | - | 626 | 533 | 792 | 723 | 835 | 778 | 982 | 920 | 749 | |
630 | - | - | 720 | 611 | 904 | 826 | 953 | 892 | 1138 | 1070 | 855 | |
800 | - | - | - | - | 1030 | 943 | 1086 | 1020 | 1265 | 1188 | 971 | |
1000 | - | - | - | - | 1154 | 1058 | 1216 | 1149 | 1420 | 1337 | 1079 |
*With or without protective conductor
Note: Rating factors for ambient temperature other than 30℃ please referTable A
Group Rating Factor please refer to Table G Voltage Drop (Per Amp Per Meter) PVC & PVC/PVC Cables
Conductor cross-sectional area (mm²) | 2 cables dc (mV/A/m) | 2 cables-single-phase ac | 3 or 4 cables-three-phase ac | |||||||||||||||||||
Reference Methods 3 &4 (Enclosed in conduit etc in or on a wall) (mV/A/m) | Reference Methods 1 & 11 (Clipped direct or on trays, touching) (mV/A/m) | Reference Methods 12 (space*) (mV/A/m) | Reference Methods 3 &4 (Enclosed in conduit etc in or on a wall) (mV/A/m) | Reference Methods 1, 11 & 12 (in trefoil) (mV/A/m) | Reference Methods 1 & 11 (Flat touching) (mV/A/m) | Reference Methods 12 (Flat spaced*) (mV/A/m) | ||||||||||||||||
1 | 44 | 44 | 44 | 44 | 38 | 38 | 38 | 38 | ||||||||||||||
1.5 | 29 | 29 | 29 | 29 | 25 | 25 | 25 | 25 | ||||||||||||||
2.5 | 18 | 18 | 18 | 18 | 15 | 15 | 15 | 15 | ||||||||||||||
4 | 11 | 11 | 11 | 11 | 9.5 | 9.5 | 9.5 | 9.5 | ||||||||||||||
6 | 7.3 | 7.3 | 7.3 | 7.3 | 6.4 | 6.4 | 6.4 | 6.4 | ||||||||||||||
10 | 4.4 | 4.4 | 4.4 | 4.4 | 3.8 | 3.8 | 3.8 | 3.8 | ||||||||||||||
16 | 2.8 | 2.8 | 2.8 | 2.8 | 2.4 | 2.4 | 2.4 | 2.4 | ||||||||||||||
r | x | z | r | x | z | r | x | z | r | x | Z | r | x | z | r | x | z | r | x | z | ||
25 | 1.75 | 1.80 | 0.33 | 1.8 | 1.75 | 0.20 | 1.75 | 1.75 | 0.29 | 1.80 | 1.50 | 0.29 | 1.55 | 1.50 | 0.175 | 1.50 | 1.50 | 0.25 | 1.55 | 1.50 | 0.32 | 1.55 |
35 | 1.25 | 1.30 | 0.31 | 1.3 | 1.25 | 0.195 | 1.25 | 1.25 | 0.28 | 1.30 | 1.10 | 0.27 | 1.10 | 1.10 | 0.170 | 1.10 | 1.10 | 0.24 | 1.10 | 1.10 | 0.32 | 1.15 |
50 | 0.93 | 0.95 | 0.30 | 1.00 | 0.93 | 0.190 | 0.95 | 0.93 | 0.28 | 0.97 | 0.81 | 0.26 | 0.85 | 0.80 | 0.165 | 0.82 | 0.80 | 0.24 | 0.84 | 0.80 | 0.32 | 0.86 |
70 | 0.63 | 0.65 | 0.29 | 0.72 | 0.63 | 0.185 | 0.66 | 0.63 | 0.27 | 0.69 | 0.56 | 0.25 | 0.61 | 0.55 | 0.160 | 0.57 | 0.55 | 0.24 | 0.60 | 0.55 | 0.31 | 0.63 |
95 | 0.46 | 0.49 | 0.28 | 0.56 | 0.47 | 0.180 | 0.50 | 0.47 | 0.27 | 0.54 | 0.42 | 0.24 | 0.48 | 0.41 | 0.155 | 0.43 | 0.41 | 0.23 | 0.47 | 0.40 | 0.31 | 0.51 |
120 | 0.36 | 0.39 | 0.27 | 0.47 | 0.37 | 0.175 | 0.41 | 0.37 | 0.26 | 0.45 | 0.33 | 0.23 | 0.41 | 0.32 | 0.150 | 0.36 | 0.32 | 0.23 | 0.40 | 0.32 | 0.30 | 0.44 |
150 | 0.29 | 0.31 | 0.27 | 0.41 | 0.30 | 0.175 | 0.34 | 0.29 | 0.26 | 0.39 | 0.27 | 0.23 | 0.36 | 0.26 | 0.150 | 0.30 | 0.26 | 0.23 | 0.34 | 0.26 | 0.30 | 0.40 |
185 | 0.23 | 0.25 | 0.27 | 0.37 | 0.24 | 0.170 | 0.29 | 0.24 | 0.26 | 0.35 | 0.22 | 0.23 | 0.32 | 0.21 | 0.145 | 0.26 | 0.21 | 0.22 | 0.31 | 0.21 | 0.30 | 0.36 |
240 | 0.180 | 0.195 | 0.26 | 0.33 | 0.185 | 0.165 | 0.25 | 0.185 | 0.25 | 0.31 | 0.17 | 0.23 | 0.29 | 0.160 | 0.145 | 0.22 | 0.160 | 0.22 | 0.27 | 0.160 | 0.29 | 0.34 |
300 | 0.145 | 0.160 | 0.26 | 0.31 | 0.150 | 0.165 | 0.22 | 0.150 | 0.25 | 0.29 | 0.14 | 0.23 | 0.27 | 0.130 | 0.140 | 0.190 | 0.130 | 0.22 | 0.25 | 0.130 | 0.29 | 0.32 |
400 | 0.105 | 0.130 | 0.26 | 0.29 | 0.120 | 0.160 | 0.20 | 0.115 | 0.25 | 0.27 | 0.12 | 0.22 | 0.25 | 0.105 | 0.140 | 0.175 | 0.105 | 0.21 | 0.24 | 0.100 | 0.29 | 0.31 |
500 | 0.086 | 0.110 | 0.26 | 0.28 | 0.098 | 0.155 | 0.185 | 0.093 | 0.24 | 0.26 | 0.10 | 0.22 | 0.25 | 0.086 | 0.135 | 0.160 | 0.086 | 0.21 | 0.23 | 0.081 | 0.29 | 0.30 |
630 | 0.068 | 0.094 | 0.25 | 0.27 | 0.081 | 0.155 | 0.175 | 0.076 | 0.24 | 0.25 | 0.08 | 0.22 | 0.24 | 0.072 | 0.135 | 0.150 | 0.072 | 0.21 | 0.22 | 0.066 | 0.28 | 0.29 |
800 | 0.053 | - | - | - | 0.068 | 0.150 | 0.165 | 0.061 | 0.24 | 0.25 | - | - | - | 0.060 | 0.130 | 0.145 | 0.060 | 0.21 | 0.22 | 0.053 | 0.28 | 0.29 |
1000 | 0.042 | - | - | - | 0.059 | 0.150 | 0.160 | 0.050 | 0.24 | 0.24 | - | - | - | 0.052 | 0.130 | 0.140 | 0.052 | 0.20 | 0.21 | 0.044 | 0.28 | 0.28 |
Note: r=conductor resistance at operating temperature
Z=impedance, x=reactance
Table A: Rating Factors for Other Ambient Air Temperatures (PVC Insulated)
Ambient Temperature | 25℃ | 30℃ | 35℃ | 40℃ | 45℃ | 50℃ | 55℃ | 60℃ | 65℃ | 70℃ |
---|---|---|---|---|---|---|---|---|---|---|
Rating Factor | 1.03 | 1.00 | 0.94 | 0.87 | 0.79 | 0.71 | 0.61 | 0.50 | 0.35 | - |
Reference Methods of Installation | Correction Factor (Cg) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Circuits or Multi-cores Cables | |||||||||||||||
2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 12 | 14 | 16 | 18 | 20 | ||
Enclosed (Method 3 or 4) or bunched and clipped direct to a non-metallic surface (Method 1) | 0.80 | 0.70 | 0.65 | 0.60 | 0.57 | 0.54 | 0.52 | 0.50 | 0.48 | 0.45 | 0.43 | 0.41 | 0.39 | 0.38 | |
Single layer clipped to a non-metallic surface (Method 1) | Touching | 0.85 | 0.79 | 0.75 | 0.73 | 0.72 | 0.72 | 0.71 | 0.70 | - | - | - | - | - | - |
Spaced* | 0.94 | 0.90 | 0.90 | 0.90 | 0.90 | 0.90 | 0.90 | 0.90 | 0.90 | 0.90 | 0.90 | 0.90 | 0.90 | 0.90 | |
Single layer multi-cores on a perforated metal cable tray, vertical or horizontal(Method 11) | Touching | 0.86 | 0.81 | 0.77 | 0.75 | 0.74 | 0.73 | 0.73 | 0.72 | 0.71 | 0.70 | - | - | - | - |
Spaced* | 0.91 | 0.89 | 0.88 | 0.87 | 0.87 | - | - | - | - | - | - | - | - | - | |
Single layer single core on a perforated metal cable tray, touching (Method 11) | Horizontal | 0.90 | 0.85 | - | - | - | - | - | - | - | - | - | - | - | - |
Vertical | 0.85 | - | - | - | - | - | - | - | - | - | - | - | - | - | |
Single layer multi-cores touching on ladder supports (Method 13) | 0.86 | 0.82 | 0.80 | 0.79 | 0.78 | 0.78 | 0.78 | 0.77 | - | - | - | - | - | - |
*Space means a clearance between adjacent surfaces of at least one cable diameter (De). Where the horizontal clearance between adjacent cables exceeds 2 De, no correction factor need be applied.
Note:
- The factors in the table are applicable to group of cables all of one size. The value of current derived from application of the appropriate factors is the maximum continuous current to be carried by any of the cables in the group.
- If, due to known operating conditions, a cable is expected to carry not more than 30% of it’s grouped rating, it may be ignored for the purpose of obtaining the rating factor for the rest of the group.
For example, a group of N loaded cables would normally require a group reduction factor of Cg applied to the tabulated It. However, if M cables in the group carry loads which are not greater than 0.3CgIt amperes, the other cables can be sized by using the group rating factor corresponding to (N-M) cables. - Factors are given for single layer of cables do not apply when cables are installed in more than one layer touching each other.
- For circuits having more than one cable in parallel per phase, each set of three conductors should be considered as a circuit for the purpose of this table.