Firetox Flame Retardant Cables | |||
Firetox Flame Retardant Cables
450/750V LSZH Insulated, Non-sheathed Power Cables (single core)
FTX100 07Z1-R (CU/LSZH 450/750V Class 2)
APPLICATION
This cables are mainly used in power stations, mass transit underground passenger systems, airports,
petrochemical plants, hotels, hospitals, and high-rise buildings.
STANDARDS
Basic design to BS 7211
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2- 1*; DIN VDE 0482-265-2-1* |
---|---|
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- 004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2- 4 |
Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268- 1&2*; BS 7622-1&2* |
No Toxic gases | NES 02-713; NF C 20-454 |
Note: Asterisk * denotes superseded standard.
VOLTAGE RATING
450/750V
CABLE CONSTRUCTION
Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: LSZH compound
COLOUR CODE
Insulation colour as per bs7671
with earth conductor | without earth conductor | |
---|---|---|
2Cores | - | Brown,Blue |
3Cores | Yellow/Green,Brown,Blue | Brown,Gray,Black |
4Cores | Yellow/Green,Brown,Gray,Black | Brown,Gray,Black,Blue |
5Cores | Yellow/Green,Brown,Gray,Black,Blue | Brown,Gray,Black,Blue,Black |
above 5 Cores | Yellow/Green,Black Numbered | Black Numbered |
sheath colour: Black
Physical AND THERMAL PROPERTIES
Temperature range during operation: Max.90°C for XLPE
250°C in short-circuit for 5s max.
Minimum bending radius: 6 x Overall Diameter
CONSTRUCTION PARAMETERS
Conductor | FTX100 07Z1-R | |||
---|---|---|---|---|
No. of Core X Cross Section |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Overall Diameter |
Approx. Weight |
Noxmm2 | No./mm | mm | mm | kg/km |
1x1.5 | 7/0.53 | 0.7 | 3.1 | 23 |
1x2.5 | 7/0.67 | 0.8 | 3.7 | 35 |
1x4 | 7/0.85 | 0.8 | 4.3 | 52 |
1x6 | 7/1.04 | 0.8 | 4.8 | 73 |
1x10 | 7/1.35 | 1.0 | 6.2 | 120 |
1x16 | 7/1.70 | 1.0 | 7.2 | 180 |
1x25 | 7/2.24 | 1.2 | 9.0 | 285 |
1x35 | 19/1.53 | 1.2 | 10.2 | 375 |
1x50 | 19/1.78 | 1.4 | 12.0 | 510 |
1x70 | 19/2.14 | 1.4 | 14.0 | 720 |
1x95 | 19/2.52 | 1.6 | 16.0 | 995 |
1x120 | 37/2.03 | 1.6 | 18.0 | 1230 |
1x150 | 37/2.25 | 1.8 | 20.0 | 1520 |
1x185 | 37/2.52 | 2.0 | 22.0 | 1900 |
1x240 | 61/2.25 | 2.2 | 25.0 | 2480 |
1x300 | 61/2.52 | 2.4 | 28.0 | 3100 |
1x400 | 61.2.85 | 2.6 | 31.5 | 3950 |
1x500 | 61/3.20 | 2.8 | 35.0 | 4950 |
1x630 | 127/2.52 | 2.8 | 39.0 | 6360 |
Electrical PROPERTIES
Conductor Operating Temperature : 90°C
Ambient Temperature : 30°C
Current-Carrying Capacities (Amp)
Conductor cross- sectional area | Reference method 4 (enclosed in conduit in thermally insulating wall etc) |
Reference method 3 (enclosed in conduit on a wall or in trunking etc) |
Reference method 1 (clipped direct) |
Reference method 11 (on a perforated cable tray, horizontal or vertical) | Reference method 12 (free air) | ||||||
Horizontal flat spaced | Vertical flat spaced | Trefoil | |||||||||
2 cables, single- phase a.c. or d.c. | 3 or 4 cables, 3-phase a.c. |
2 cables, single- phase a.c. or d.c | 3 or 4 cables, 3-phase a.c. |
2 cables, single- phase a.c. or d.c. flat and touching | 3 or 4 cables, 3-phase a.c. flat and touching or trefoil |
2 cables, single- phase a.c. or d.c. or flat and touching | 3 or 4 cables, 3-phase a.c. flat and touching or trefoil |
2 cables, single- phase a.c. or d.c. or 3 c ables three phase |
2 cables, single- phase a.c. or d.c. or 3 cables three phase |
3 cables, trefoil 3-phase a.c. |
|
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
mm2 | A | A | A | A | A | A | A | A | A | A | A |
1.5 | 18 | 17 | 22 | 19 | 25 | 23 | - | - | - | - | - |
2.5 | 24 | 23 | 30 | 26 | 34 | 31 | - | - | - | - | - |
4 | 33 | 30 | 40 | 35 | 46 | 41 | - | - | - | - | - |
6 | 43 | 39 | 51 | 45 | 59 | 54 | - | - | - | - | - |
10 | 58 | 53 | 71 | 63 | 81 | 74 | - | - | - | - | - |
16 | 76 | 70 | 95 | 85 | 109 | 99 | - | - | - | - | - |
25 | 100 | 91 | 126 | 111 | 143 | 130 | 158 | 140 | 183 | 163 | 138 |
35 | 125 | 111 | 156 | 138 | 176 | 161 | 195 | 176 | 226 | 203 | 171 |
50 | 149 | 135 | 189 | 168 | 228 | 209 | 293 | 215 | 274 | 246 | 209 |
70 | 189 | 170 | 240 | 214 | 293 | 268 | 308 | 279 | 351 | 318 | 270 |
95 | 228 | 205 | 290 | 259 | 355 | 326 | 375 | 341 | 426 | 389 | 330 |
120 | 263 | 235 | 336 | 299 | 413 | 379 | 436 | 398 | 495 | 453 | 385 |
150 | 300 | 270 | 375 | 328 | 476 | 436 | 505 | 461 | 570 | 524 | 445 |
185 | 341 | 306 | 426 | 370 | 545 | 500 | 579 | 530 | 651 | 600 | 511 |
240 | 400 | 358 | 500 | 433 | 644 | 590 | 686 | 630 | 769 | 711 | 606 |
300 | 459 | 410 | 573 | 493 | 743 | 681 | 794 | 730 | 886 | 824 | 701 |
400 | - | - | 684 | 584 | 868 | 793 | 915 | 849 | 1065 | 994 | 820 |
500 | - | - | 783 | 666 | 990 | 904 | 1044 | 973 | 1228 | 1150 | 936 |
630 | - | - | 900 | 764 | 1130 | 1033 | 1191 | 1115 | 1423 | 1338 | 1069 |
Voltage Drop (Per Amp Per Meter)
Nominal Cross Section Area |
2 cables d.c. |
2 cables, single-phase a.c. | 3 or 4 cables, 3-phase a.c. | |||||||||||||
Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall) |
Ref. Methods 1 and 11 (clipped direct or on trays touching) |
Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall) |
Ref. Methods 1, 11 and 12 (in trefoil) |
Ref. Methods 1 and 11(Flat and touching) |
||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
||||||||||
mm2 |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
||||||||||
1.5 |
31 |
31 |
27 |
27 |
27 |
27 |
||||||||||
2.5 |
19 |
19 |
16 |
16 |
16 |
16 |
||||||||||
4 |
33 |
12 |
10 |
10 |
10 |
10 |
||||||||||
6 |
7.8 |
7.9 |
6.8 |
6.8 |
6.8 |
6.8 |
||||||||||
10 |
4.7 |
4.7 |
4.7 |
4 |
4 |
4 |
||||||||||
16 |
2.9 |
2.9 |
2.9 |
2.5 |
2.5 |
2.5 |
||||||||||
|
|
r |
x |
z |
r |
x |
z |
r |
x |
z |
r |
x |
z |
r |
x |
z |
25 |
1.85 |
1.85 |
0.31 |
1.9 |
1.85 |
0.19 |
1.85 |
1.6 |
0.27 |
1.65 |
1.6 |
0.165 |
1.6 |
1.6 |
0.19 |
1.6 |
35 |
1.35 |
1.35 |
0.29 |
1.35 |
1.35 |
0.18 |
1.35 |
1.15 |
0.25 |
1.15 |
1.15 |
0.155 |
1.5 |
1.15 |
0.18 |
1.15 |
50 |
0.99 |
1 |
0.29 |
1.05 |
0.99 |
0.18 |
1 |
0.87 |
0.25 |
0.9 |
0.86 |
0.155 |
0.87 |
0.86 |
0.18 |
0.87 |
70 |
0.68 |
0.7 |
0.28 |
0.75 |
0.68 |
0.175 |
0.71 |
0.6 |
0.24 |
0.65 |
0.59 |
0.15 |
0.61 |
0.59 |
0.175 |
0.62 |
95 |
0.49 |
0.51 |
0.27 |
0.58 |
0.49 |
0.17 |
0.52 |
0.44 |
0.23 |
0.5 |
0.43 |
0.145 |
0.45 |
0.43 |
0.17 |
0.46 |
120 |
0.39 |
0.41 |
0.26 |
0.48 |
0.39 |
0.165 |
0.43 |
0.35 |
0.23 |
0.42 |
0.34 |
0.14 |
0.37 |
0.34 |
0.165 |
0.38 |
150 |
0.32 |
0.33 |
0.26 |
0.43 |
0.32 |
0.165 |
0.36 |
0.29 |
0.23 |
0.37 |
0.28 |
0.14 |
0.31 |
0.28 |
0.165 |
0.32 |
185 |
0.25 |
0.27 |
0.26 |
0.37 |
0.26 |
0.165 |
0.3 |
0.23 |
0.23 |
0.32 |
0.22 |
0.14 |
0.26 |
0.22 |
0.165 |
0.28 |
240 |
0.19 |
0.21 |
0.26 |
0.33 |
0.2 |
0.16 |
0.25 |
0.185 |
0.22 |
0.29 |
0.17 |
0.14 |
0.22 |
0.17 |
0.165 |
0.24 |
300 |
0.155 |
0.175 |
0.25 |
0.31 |
0.16 |
0.16 |
0.22 |
0.15 |
0.22 |
0.27 |
0.14 |
0.14 |
0.195 |
0.135 |
0.16 |
0.21 |
400 |
0.12 |
0.14 |
0.25 |
0.29 |
0.13 |
0.155 |
0.2 |
0.125 |
0.22 |
0.25 |
0.11 |
0.135 |
0.175 |
0.11 |
0.16 |
0.195 |
500 |
0.093 |
0.12 |
0.25 |
0.28 |
0.105 |
0.155 |
0.185 |
0.1 |
0.22 |
0.24 |
0.09 |
0.135 |
0.16 |
0.088 |
0.16 |
0.18 |
630 |
0.072 |
0.1 |
0.25 |
0.27 |
0.086 |
0.155 |
0.175 |
0.088 |
0.21 |
0.23 |
0.074 |
0.135 |
0.15 |
0.071 |
0.16 |
0.17 |