Lan Cables  
Cat5e Cable Cat6 Cable Cat7 Cable more

Lan Cables

Product Name/Code: FTP Cat 6 PVC Performance
Application: Frequency RL Attenuation NEXT PSNEXT
100 Base-T4 (MHz) (dB) (dB/100m)
100 Base-TX min. max min (dB) min (dB)
100VG - AnyLAN 1.000 20.00 2.00 74.30 72.30
1000 Base-T (Gigabit Ethernet) 4.000 23.00 3.80 65.30 63.30
155 Mbps ATM 8.000 24.50 5.30 60.80 58.80
622 Mbps AT 10.00 25.00 6.00 59.30 57.30
Reference Standard 16.00 25.00 7.60 56.20 54.20
EIA/TIA 568B & ISO/IEC 11801 20.00 25.00 8.50 54.80 52.80
Cable Construction 25.00 24.30 9.50 53.30 51.30
Conductor Solid Bare Copper 31.25 23.60 10.70 51.90 49.90
AWG 23 62.50 21.50 15.40 47.40 45.40
Conductor Diameter(mm) 0.574 100.00 20.10 19.80 44.30 42.30
Insulation Solid PE 200.00 18.00 29.00 39.80 37.80
250.00 17.30 32.80 38.30 36.30
Average Thickness (mm) 0.2 Frequency ELFEXT PSELFEXT ACR
Insulation Diameter(mm) 1.00 (MHz)
Drain wire Tinned copper min (dB) min (dB)
Construction (mm) 7/0.2 1.000 67.80 64.80 72.30
Al foil Aluminium/PET fiol 4.000 55.80 52.80 61.50
8.000 49.70 46.70 55.50
10.00 47.80 44.80 53.30
Sheathing PVC /FRPVC 16.00 43.70 40.70 48.60
Thickness(mm) 1.1 20.00 41.80 38.80 46.30
Diameter(mm) 6.1 25.00 39.80 36.80 43.80
31.25 37.90 34.90 41.20
Core Identificatin/Color Code According to customer request 62.50 31.90 28.90 32.00
Bending Radius 6xOverall Diameter 100.00 27.80 24.80 24.50
200.00 21.80 18.80 10.80
250.00 19.80 16.80 5.50
Fire Performance Electrical Performance
Flame propagation Test to IEC 332 Part 1(PVC)
Flame Propagation Test to IEC 60332 Part 1 and Part 3
Max.Conductor DC Resistance at 20 ℃(Ω/Km) <93.8
Operating Temperature( ℃ ) 70
Velocity of propagation 74%
Impedance(ohm) 100±15
Website: www.caledonian-cables.net
E-mail: sales@caledonian-cables.net