Marine, OIL,GAS & Petrochemical Cables | |||
Norwegian Offshore cables | BritishStandard Shipwiringcable | British Standard Fire resistant Shipwiring cable | European lightweight marine cable |
Norwegian Offshore cables to NEK 606
RFOU Instrumentation IEC60092-376
Designed for use in petrochem and offshore instrumentation applications RFOU is available in collectively or
individually screened options for optimum EMI suppression.These new reduced outer diameter versions of RFOU
allow cable routing through more confined spacesand offer considerable weight savings over the traditional
IEC60092-3 type.
The individually screened version has a copper backed polyester tape with a stranded copper drain wire
0.75mm² around each pair or triple.
Standards
IEC60092-353: electrical installation in ships, power cables, NEK606: cables for offshore installation halogen-
free or mud-resistant, IEC60092.375 shipboard telecommunications cable, IEC60331: fire resistant, IEC60332:
flame retardant, IEC61031-1.2: smoke denisty, IEC60754-1, halogen free properties, & IEC60228: electical
conductor
Technical Information
Voltage: 250V
Operating temperature:Maximum 85°C, minimium bending -40°C
Bending Radius Static:6 x cable diameter
Oxygen index of sheath:> 31%
Technical Data
Pairs & mm² |
Weight Kg/Km |
O/D mm |
---|---|---|
Collectively Screened Pairs | ||
2 x 2 x 0.75 | 280 | 13.0 |
4 x 2 x 0.75 | 400 | 15.0 |
8 x 2 x 0.75 | 620 | 19.0 |
12 x 2 x 0.75 | 800 | 22.0 |
16 x 2 x 0.75 | 960 | 23.0 |
24 x 2 x 0.75 | 1375 | 28.0 |
2 x 2 x 1.5 | 425 | 16.0 |
4 x 2 x 1.5 | 575 | 18.0 |
8 x 2 x 1.5 | 930 | 23.5 |
12 x 2 x 1.5 | 1190 | 27.0 |
16 x 2 x 1.5 | 1500 | 29.0 |
24 x 2 x 1.5 | 2200 | 36.0 |
Individually Screened Pairs | ||
1 x 2 x 0.75 | 195 | 10.0 |
2 x 2 x 0.75 | 295 | 13.0 |
4 x 2 x 0.75 | 450 | 15.0 |
8 x 2 x 0.75 | 720 | 19.5 |
12 x 2 x 0.75 | 940 | 22.5 |
16 x 2 x 0.75 | 1185 | 25.0 |
24 x 2 x 0.75 | 1650 | 30.5 |
1 x 2 x 1.5 | 230 | 11.5 |
2 x 2 x 1.5 | 440 | 16.0 |
4 x 2 x 1.5 | 620 | 18.0 |
8 x 2 x 1.5 | 1025 | 23.5 |
12 x 2 x 1.5 | 1365 | 28.0 |
16 x 2 x 1.5 | 1730 | 31.0 |
24 x 2 x 1.5 | 2650 | 38.5 |
Triples & mm² |
Weight Kg/Km |
O/D mm |
---|---|---|
Collectively Screened Triples | ||
2 x 3 x 0.75 | 365 | 14.0 |
4 x 3 x 0.75 | 485 | 16.5 |
8 x 3 x 0.75 | 780 | 21.0 |
12 x 3 x 0.75 | 990 | 24.0 |
16 x 3 x 0.75 | 1240 | 26.0 |
24 x 3 x 0.75 | 1800 | 32.0 |
2 x 3 x 1.5 | 505 | 17.0 |
4 x 3 x 1.5 | 695 | 19.0 |
8 x 3 x 1.5 | 1190 | 25.0 |
12 x 3 x 1.5 | 1560 | 29.0 |
16 x 3 x 1.5 | 1940 | 32.0 |
24 x 3 x 1.5 | 2900 | 40.0 |
Individually Screened Triples | ||
1 x 3 x 0.75 | 205 | 10.5 |
2 x 3 x 0.75 | 385 | 14.5 |
4 x 3 x 0.75 | 525 | 16.5 |
8 x 3 x 0.75 | 875 | 21.0 |
12 x 3 x 0.75 | 1170 | 25.0 |
16 x 3 x 0.75 | 1450 | 28.0 |
24 x 3 x 0.75 | 2100 | 34.5 |
1 x 3 x 1.5 | 275 | 12.0 |
2 x 3 x 1.5 | 530 | 17.5 |
4 x 3 x 1.5 | 770 | 20.0 |
8 x 3 x 1.5 | 585 | 25.5 |
12 x 3 x 1.5 | 1740 | 31.0 |
16 x 3 x 1.5 | 2270 | 35.0 |
24 x 3 x 1.5 | 3400 | 43.0 |