IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Cat 5e S/FTP 0.22mm²

Application

Marine Cat5e S/FTP cables are manufactured in accordance with IEC 61156-5 requirements, can support all

Class D applications like Ethernet, Fast Ethernet, Gigabit Ethernet, suitable for basic voice and data installations

up to 100MHz.

Standards

EN 50173-1

EN 50288-2-1

ISO/IEC 11801

IEC 61156-5

IEC 60332-3-24

IEC 60754-1/2

IEC 61034-1/2

Construction

IEC60092 Offshore & Marine Cables

Conductors: Stranded copper conductor.

Insulation: PE.

Twinning: Two coloured insulated conductors twisted together to form a pair.

Individual Screen: Al/polyester tape.

Overall Screen: Tinned copper wire braid.

Outer Sheath: Oil resistant, flame retardant and halogen free LSOH (SHF1).

Core Identification

Pair 1: White, Blue

Pair 2: White, Orange

Pair 3: White, Green

Pair 4: White, Brown

Electrical Properties

Characteristic Impedance(1-100MHz) Ω 100±15
Nominal Velocity of Propagation(NVP)   69%
Maximum Mutual Capacitance nF/100m 5.6
Maximum Capacitance Unbalance pF/100m 330
Maximum Resistance Unbalance   5%
Maximum Propagation Delay Skew ns/100m 30
Maximum Propagation Delay@100MHz ns/100m 536
Voltage Rating V rms 80
Nominal Transmission Characteristics @20℃
FREQ NEXT Attenuation RL ACR ELFEXT PSNEXT PSACR PSELFEXT
MHz dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m
1 65.3 2.0 20.2 63.3 63.8 62.3 60.3 60.8
4 56.3 4.1 23.0 52.2 51.7 53.3 49.2 48.7
8 51.8 5.8 24.5 46 45.7 48.8 43 42.7
10 50.3 6.5 25.0 43.8 43.8 47.3 40.8 40.8
16 47.3 8.2 25.0 39.1 39.7 44.3 36.1 36.7
20 45.8 9.3 25.0 36.5 37.7 42.8 33.5 34.7
25 44.3 10.4 24.3 33.9 35.8 41.3 30.9 32.8
31.25 42.9 11.7 23.6 31.2 33.9 39.9 28.2 30.9
62.5 38.4 17.0 21.5 21.4 27.8 35.4 18.4 24.8
100 35.3 22.0 20.1 13.3 23.8 32.3 10.3 20.8
155 32.5 28.1 18.8 4.4 19.9 29.5 -1.4 16.9
200 30.7 32.4 18.0 -1.7 18.7 27.7 -4.7 15.7
310 29.3 41.8 17.3 N/A 10.0 26.3 N/A 13.0
350 27.1 44.9 17.3 N/A 7.1 24.1 N/A 10.1

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 4×OD (fixed installed)

Temperature Range: -40℃ ~ +85℃

Dimensions and Weight

Part No. Construction
No. of elements×No. of cores in element×Cross section
(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
MLN-S/FTPCAT5E4P22S 4×2×0.22 0.4 0.75 7.7 68