IEC60092 Offshore & Marine Cables | |||
MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
CAN BUS CABLES 120Ω
Application
Marine cables are dedicated to the shipbuilding industry.
Standards
IEC 60092-350/360/352/353/370 /376
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1/2
IEC 61034
Construction
Conductors: Stranded tinned copper 21AWG.
Insulation: Foam skin PP.
Inner Sheath: Thermoplastic copolymer (FRNC).
Overall Screen1: Aluminium/polyester tape.
Overall Screen2: Tinned copper braid.
Outer Sheath: LSOH (SHF1).
Core Identification
Pair 1: Blue, Red
Pair 2: Brown, Green
Electrical Properties
Characteristic Impedance | Ω | 120 ± 18 | |
---|---|---|---|
Mutual Capacitance @1KHz | nF/km | 36 | |
Insulation Resistance | GΩ.km | 5 | |
1 pair | 2 pair | ||
Attenuation @0.1MHz | dB/100m | 0.65 | 0.3 |
Attenuation @1MHz | dB/100m | 1.9 | 1.1 |
Attenuation @5MHz | dB/100m | 4.3 | 2.8 |
Attenuation @10MHz | dB/100m | 8.1 | 3.9 |
Attenuation @20MHz | dB/100m | 10.5 | 5.7 |
Mechanical and Thermal Properties
Bending Radius for Fixed Installations: 10×OD
Temperature Range: -30℃ ~ +80℃
Dimensions and Weight
Part No. | Construction No. of elements×No. of cores in element×Cross section mm² |
Core Diameter mm | Nominal Overall Diameter mm |
Nominal Weight kg/km |
---|---|---|---|---|
MLN-09YSH(ST)CH-1×2×21A | 1×2×21 AWG | 2.4 | 7.7 | 79 |
MLN-09YSH(ST)CH-2×2×21A | 2×2×21 AWG | 2.2 | 8.4 | 90 |