Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

M2XH-FFR

0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Power & Control Cables (Multicore)

Applications

Marine unarmoured fire resistant cables are used on board of ships in all locations for fixed installations where

cable protection is not required. Marine cables are fire resistant, flame retardant, low smoke & halogen free.

Standards

IEC 60092-350/360/353

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1/2

IEC 61034

Construction

IEC60092 Offshore & Marine Cables

Conductors:Class 2 stranded copper conductor. Class 5 stranded conductors can be offered upon request.

Insulation:Mica tape + XLPE.

Outer Sheath:LSOH (SHF1).

Core Identification

Two cores:Blue, Brown.

Three cores:Brown, Black, Grey.

Four cores:Blue, Brown, Black, Grey.

Five cores:Blue, Brown, Black, Grey, Black.

Multi cores:White with black numbers.

Mechanical and Thermal Properties

Bending Radius for Fixed Installations:6×OD (OD>25mm); 4×OD (OD ≤25mm)

Temperature Range:-30℃ ~ +80℃

Dimensions and Weight

M2XH-FFR Multicore 0.6/1kV

Part No. Construction No. of elements×No. of cores in element×Cross section Nominal Insulation Thickness Nominal Sheath Thickness Nominal Overall Diameter Nominal Weight
  mm² mm mm mm kg/km
M2XH-FFR -2C1.5 2×1.5 0.7 1.1 8.5 85
M2XH-FFR -2C2.5 2×2.5 0.7 1.1 9.5 110
M2XH-FFR -2C4 2×4 0.9 1.1 11.7 140
M2XH-FFR -2C6 2×6 0.9 1.2 13.0 230
M2XH-FFR -2C10 2×10 0.9 1.2 14.7 330
M2XH-FFR -2C16 2×16 0.9 1.3 17.0 490
M2XH-FFR -2C25 2×25 0.9 1.3 19.5 750
M2XH-FFR -2C35 2×35 0.9 1.5 22.0 990
M2XH-FFR -2C50 2×50 1.0 1.5 24.8 1340
M2XH-FFR -3C1.5 3×1.5 0.7 1.1 9.5 105
M2XH-FFR -3C2.5 3×2.5 0.7 1.1 10.0 145
M2XH-FFR -3C4 3×4 0.9 1.2 12.7 205
M2XH-FFR -3C6 3×6 0.9 1.2 13.9 270
M2XH-FFR -3C10 3×10 0.9 1.3 15.9 400
M2XH-FFR -3C16 3×16 0.9 1.3 18.4 610
M2XH-FFR -3C25 3×25 0.9 1.5 21.4 920
M2XH-FFR -3C35 3×35 0.9 1.6 24.2 1330
M2XH-FFR -3C50 3×50 1.0 1.7 27.5 1830
M2XH-FFR -3C70 3×70 1.1 1.8 32.0 2570
M2XH-FFR -3C70S 3×70 (sector shaped) 1.1 1.8 27.5 2370
M2XH-FFR -3C95 3×95 1.1 1.9 36.4 3360
M2XH-FFR -3C95S 3×95 (sector shaped) 1.1 1.9 31.1 3130
M2XH-FFR -3C120 3×120 1.2 2.1 40.7 4180
M2XH-FFR -3C120S 3×120 (sector shaped) 1.2 2.1 34.4 3930
M2XH-FFR -4C1.5 4×1.5 0.7 1.1 10.0 135
M2XH-FFR -4C2.5 4×2.5 0.7 1.1 11.2 180
M2XH-FFR -4C4 4×4 0.9 1.2 13.9 260
M2XH-FFR -4C6 4×6 0.9 1.2 15.2 350
M2XH-FFR -4C10 4×10 0.9 1.3 17.4 530
M2XH-FFR -4C16 4×16 0.9 1.4 20.2 800
M2XH-FFR -4C25 4×25 0.9 1.5 23.5 1230
M2XH-FFR -4C35 4×35 0.9 1.7 26.7 1650
M2XH-FFR -5C1.5 5×1.5 0.7 1.1 11.0 170
M2XH-FFR -7C1.5 7×1.5 0.7 1.2 12.6 210
M2XH-FFR -12C1.5 12×1.5 0.7 1.3 16.5 350
M2XH-FFR -19C1.5 19×1.5 0.7 1.4 19.6 520
M2XH-FFR -27C1.5 27×1.5 0.7 1.5 23.3 730
M2XH-FFR -37C1.5 37×1.5 0.7 1.6 26.3 980
M2XH-FFR -5C2.5 5×2.5 0.7 1.2 12.5 240
M2XH-FFR -7C2.5 7×2.5 0.7 1.2 14.1 300
M2XH-FFR -12C2.5 12×2.5 0.7 1.3 18.6 490
M2XH-FFR -19C2.5 19×2.5 0.7 1.4 22.1 750
M2XH-FFR -27C2.5 27×2.5 0.7 1.5 26.4 1060