IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Water Blocked

P16 IFLI 250 V

Applications

Marine cables are flame retardant, low smoke and halogen free, used for living, quarter and office areas.

Standards

IEC 60092-376

IEC 60092-360

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606

VG 95218 part 29

P16 IFLI 250 V

Construction

Conductors: Circular stranded copper wire to IEC 60228 class 2.

Insulation: XLPE.

Filler: Water blocking fillers, if required.

Bedding: Halogen free thermoplastic compound.

Metal Screen: Longitudinal aluminium tape, thickness 0.2 mm in contact with a stranded copper earth

conductor, PETP wrapping tape will be applied over the bedding, if required.

Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness.

Inner Sheath: Halogen free thermoplastic compound, SHF1, coloured grey.

Outer Sheath: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low

smoke standard.

Electrical Characteristics

Mechanical and Thermal Properties

Bending Radius : 8×OD (during installation); 6×OD (fixed installed).

Construction
No. of elements×No. of cores in element×Cross section
mm²
Nominal
Insulation Thickness
mm
Nominal
Bedding Thickness
mm
Nominal
Inner Sheath Thickness
mm
Nominal
Outer Sheath Thickness
mm
Nominal
Overall Diameter
mm
Nominal Weight
kg/km
2×1×2.5 0.7 1.1 1.2 1.0 12.0±2 189