IEC60092 Offshore & Marine Cables | |||
MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
Water Blocked
P16 IFLI 250 V
Applications
Marine cables are flame retardant, low smoke and halogen free, used for living, quarter and office areas.
Standards
IEC 60092-376
IEC 60092-360
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606
VG 95218 part 29
Construction
Conductors: Circular stranded copper wire to IEC 60228 class 2.
Insulation: XLPE.
Filler: Water blocking fillers, if required.
Bedding: Halogen free thermoplastic compound.
Metal Screen: Longitudinal aluminium tape, thickness 0.2 mm in contact with a stranded copper earth
conductor, PETP wrapping tape will be applied over the bedding, if required.
Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness.
Inner Sheath: Halogen free thermoplastic compound, SHF1, coloured grey.
Outer Sheath: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low
smoke standard.
Electrical Characteristics
-
Nominal Cross Section Area mm² 2.5 Maximum Resistant@20℃ Ω/km 7.41 Continuous Current Rating@45℃2 Core A 26 Short Circuit Current 1s A 360 Operating Voltage V 250
Mechanical and Thermal Properties
Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
-
Temperature Range : -20℃ ~ +90℃.
-
Dimensions and Weight
Construction No. of elements×No. of cores in element×Cross section mm² |
Nominal Insulation Thickness mm |
Nominal Bedding Thickness mm |
Nominal Inner Sheath Thickness mm |
Nominal Outer Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
---|---|---|---|---|---|---|
2×1×2.5 | 0.7 | 1.1 | 1.2 | 1.0 | 12.0±2 | 189 |